How to Replace a SPARC T4-4 Processor Module:ATR:1480012.1:2
Related Items |
- SPARC SuperCluster T4-4 Full Rack
- SPARC SuperCluster T4-4 Half Rack
- SPARC SuperCluster T4-4
- SPARC T4-4
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
How to remove and replace a SPARC T4-4 Server Processor Module
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP
Applies to:
SPARC SuperCluster T4-4 - Version All Versions and later
SPARC T4-4 - Version All Versions and later
SPARC SuperCluster T4-4 Full Rack - Version All Versions and later
SPARC SuperCluster T4-4 Half Rack - Version All Versions and later
Information in this document applies to any platform.
Goal
Remove and replace a SPARC T4-4 Processor Module.
*********************************************************************
To report errors or request improvements on this procedure,
please Add a Comment on Doc ID: 1480012.1
*********************************************************************
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
Qualified service technicians with SPARC T4-4 experience/training.
Time Estimate: 60 minutes
Task Complexity: 1
FIELD ENGINEER INSTRUCTIONS
PROBLEM OVERVIEW: replace a faulty SPARC T4-4 Processor Module
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
The server must be fully shut down and the power cords disconnected.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
DAMAGE ALERT: Perform a visual inspection of the replacement part to make sure that there are no damaged components, connectors, bent pins, damaged packages during shipping, etc). If the part is damaged, don't install it into the system, order a new part. Handle with caution and package carefully the return part to avoid any damages during shipping.
NOTE: Before parts replacement, connectors pins should be inspected to make sure there are no bent pins and/or misaligned connectors, as that can cause a number of problematic symptoms.
Remove a Processor Module:
Squeeze the release latches together on the two extraction levers and pull the extraction levers out to disengage the processor module from the server.
Pull the processor module halfway out of the server.
Press the levers back together, toward the center of the processor module.
This will keep the levers from getting damaged when you remove the processor module from the server.
Using two hands, completely remove the processor module and place the module on an antistatic mat.
Caution - Do not touch the connectors at the rear of the processor module.
Remove the cover from the processor module:
Press down on the green button at the top of the cover to disengage the cover from the processor module.
Keeping the button pressed down, push the cover toward the rear of the processor module and lift the cover up and away from the processor module.
Remove all DIMMs from the faulty processor module and set them in a safe place.
Install a Processor Module:
Install all of the DIMMs that you removed from the faulty processor module into the replacement module.
Insert the processor module into the empty processor module slot in the server.
Bring the levers together toward the center of the module and press them firmly against the module to fully seat the module back into the server.
The levers should click into place when the module is fully seated in the server.
Power on the server.
Use the show faulty command to determine if the replaced processor module is shown as enabled or disabled:
-> show faulty
If the output from the show faulty command shows the replacement processor module as disabled see http://docs.oracle.com/cd/E23411_01/html/E23412/z400002a9112.html#scrolltoc
Verify that the OK LED is lit on the processor module and that the Fault LED is not lit. Verify that the front and rear Service Required LEDs are not lit.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE FE/CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Boot system and monitor boot sequence for errors. Test functionality of system:
1. Run the Solaris "fmadm faulty" and SP/ILOM "show faulty" command (if only ALOM is supported run "showfaults -v" command) to verify that the fault has been cleared.
2. Perform one of the following tasks based on your verification results:
* If the previous steps did not clear the fault, refer to doc 1004229.1 for information about the tools and methods you can use to diagnose and clear component faults.
* If the previous steps indicate that no faults have been detected, then the component has been replaced successfully. No further action is required
3. Restart software applications per applicable administration guides to resume system operation.
PARTS NOTE:
refer to: https://support.oracle.com/handbook_partner/Systems/SPARC_T4_4/components.html#CPUModule
REFERENCE INFORMATION:
SPARC T4-4 Service Manual: http://docs.oracle.com/cd/E23411_01/index.html