Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1479968.1
Update Date:2017-11-30
Keywords:

Solution Type  Technical Instruction Sure

Solution  1479968.1 :   How to Remove and Replace Netra 240 Front CPU/Memory Blower Assembly:ATR:1479968.1:0  


Related Items
  • Sun Netra 240 (DC) Server
  •  
  • Sun Netra 240 (AC) Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
Goal
Solution


Applies to:

Sun Netra 240 (AC) Server - Version All Versions to All Versions [Release All Releases]
Sun Netra 240 (DC) Server - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

  Netra 240, How to Remove and Replace Front CPU/Memory Blower Assembly

Solution

 

DISPATCH INSTRUCTIONS


WHAT SKILLS ARE REQUIRED:
No special skills required, Customer Replaceable Unit (CRU) procedure

TASK COMPLEXITY: 0

TIME ESTIMATE: 45 minutes
 

REMOVAL/REPLACEMENT INSTRUCTIONS

PROBLEM OVERVIEW: Front CPU/Memory Blower Assembly failure

OBTAIN CUSTOMER ACCEPTANCE

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.

 WHAT ACTIONS ARE REQUIRED:

Replacing the Front CPU/Memory Blower Assembly

The front fan assembly tray or Front CPU/Memory Blower Assembly is located behind the rotating service module. The front fan assembly tray contains two fans, F2 and F3. The entire front fan assembly tray should be replaced if one of these fans fail.

1.Power off the server.

2.Remove the server cover.

3.Open the rotating service module.

4.Ensure that the server is properly grounded.

5.Detach the two front fan assembly cables from the system board connectors

6.Using a No. 2 Phillips screwdriver, loosen the green captive screw that secures the front fan assembly tray to the rotating service module

7.Lift the front fan assembly tray straight up and remove it from the server

 Installing Front CPU/Memory Blower Assembly

1.Place the front fan assembly tray into position in the rotating service module

2.Tighten the captive screw to secure the front fan assembly tray to the rotating service module

3.Connect the two cables to the system board and route it behind the post

4.Close the rotating service module.

5.Install the server cover.

6. Plug in power & power up system to return the server to operation line

 

 

WHAT ACTIONS ARE REQUIRED TO RETURN the SYSTEM TO AN OPERATIONAL STATE:

Restart software applications per applicable administration guides to resume system operation.



PARTS NOTE: Include Front CPU/Memory Blower Assembly location

https://support.oracle.com/handbook_private/Systems/Netra_240/components.html#Fan

https://support.oracle.com/handbook_private/Systems/Netra_240_R/components.html#Fan

 

ADDITIONAL COMMENTS: