![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Technical Instruction Sure Solution 1479532.1 : Drives Show Faulted In BUI "Configuration -> Storage" Screen when cache (readzilla) disks are physically located on another node
In this Document
Created from <SR 3-5861645711> Applies to:Oracle Exalogic Elastic Cloud X2-2 Hardware - Version X2 and laterInformation in this document applies to any platform. GoalIn Sun ZFS Storage 7320 Browser User Interface (BUI) ( https://[IP address or host name you assigned to the SolutionThis is normal and expected reporting of the ZFSSA Pool when cache (readzilla) disks are physically located on the other node.
bash-4.1$ more hw.aksh
Chassis: NAME STATE MANUFACTURER MODEL SERIAL RPM chassis-000 ok Oracle Sun ZFS Storage 7320 <Serial Number> -- cpu-000 CPU 0 ok Intel Intel(r) Xeon(r) CPU E5620 @ 2.40GHz unknown cpu-001 CPU 1 ok Intel Intel(r) Xeon(r) CPU E5620 @ 2.40GHz unknown disk-000 HDD 0 ok SEAGATE ST95000NSSUN500G 9SP2ABKM 7200 disk-001 HDD 1 ok SEAGATE ST95000NSSUN500G 9SP2AFB3 7200 disk-002 HDD 2 ok TOSHIBA THNS512GG8BBAA 11NS106OTBUZ -- disk-003 HDD 3 ok TOSHIBA THNS512GG8BBAA 11NS105UTBUZ -- disk-004 HDD 4 ok TOSHIBA THNS512GG8BBAA Z0NS1012TBUZ -- disk-005 HDD 5 ok TOSHIBA THNS512GG8BBAA Z0NS1050TBUZ -- bash-4.1$ more hw.aksh Chassis: NAME STATE MANUFACTURER MODEL SERIAL RPM chassis-000 u1eis04nasx07 ok Oracle Sun ZFS Storage 7320 <Serial Number> -- disk-000 HDD 0 ok SEAGATE ST95000NSSUN500G 9SP2ABG8 7200 disk-001 HDD 1 ok SEAGATE ST95000NSSUN500G 9SP2AF5L 7200 disk-002 HDD 2 ok TOSHIBA THNS512GG8BBAA Z0NS1051TBUZ -- disk-003 HDD 3 ok TOSHIBA THNS512GG8BBAA Z0NS1053TBUZ -- disk-004 HDD 4 ok TOSHIBA THNS512GG8BBAA 70ES100CTBUZ -- disk-005 HDD 5 ok TOSHIBA THNS512GG8BBAA 11NS106TTBUZ -- cache
c2t2d0 ONLINE 0 0 0 c2t3d0 ONLINE 0 0 0 c2t4d0 ONLINE 0 0 0 c2t5d0 ONLINE 0 0 0 c2t2d0 FAULTED 0 0 0 corrupted data c2t3d0 FAULTED 0 0 0 corrupted data cache devices are available only to the node which has the storage pool imported. c2t4d0 FAULTED 0 0 0 corrupted data At takeoover these drives will report online and the other disks as Faulted corrupted data c2t5d0 FAULTED 0 0 0 corrupted data
In the help on the Browser User Interface (BUI) https://[hostname]:215/wiki/index.php/Configuration:Storage -- under Profile Configuration there is an explanation of "In a cluster, cache devices are available only to the node which has the storage pool imported."
References<NOTE:1333120.1> - Sun Storage 7000 Unified Storage System: How to add L2ARC cache SSDs (Readzillas) to a poolAttachments This solution has no attachment |
||||||||||||||||
|