Asset ID: |
1-71-1479513.1 |
Update Date: | 2018-05-17 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1479513.1
:
How to Replace a Sun Server X2-4 (Sun Fire X4470 M2) Power Supply [VCAP]
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Applies to:
Sun Server X2-4 - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to Replace a Sun Server X2-4 (Sun Fire X4470 M2) Power Supply.
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
No special skills required, Customer Replaceable Unit (CRU) procedure
TIME ESTIMATE: 30 minutes
TASK COMPLEXITY: 0
FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
PROBLEM OVERVIEW: A Sun Server X2-4 (Sun Fire X4470 M2) Power Supply needs replacement
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
Sun Server X2-4 has redundant power supplies enable you to
remove and replace a power supply without shutting down the server, provided that
the other power supply is online and working.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Attach an antistatic wrist strap.
2. Identify which power supply (0 or 1) requires replacement.
3. Disconnect the power cord from the faulty power supply.
4. Press down on the release latch and slide the power supply out of the chassis.
5. Installation is the reverse of this procedure.
6. Verify that the AC Present LED is lit.
7. Verify that the following LEDs are not lit:
■ Service Action Required LED on the power supply
■ Front and rear Service Action Required LEDs
■ Rear PS Failure LED on the bezel of the server
CAUTION:
Whenever you remove a power supply, you should replace it with
another power supply; otherwise, the server might overheat due to improper airflow.
If a new power supply is not available, leave the failed power supply installed until
it can be replaced.
Install an A239A or A239C power supply, labeled for upright installation,
in the Sun Server X2-4. The A239A/A239C power supply correctly exhausts air from
the rear of the server. Do not install an A239 or A239B power supply, which might
cause the system to overheat and shut down.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:Verify AC present LED is lit.Verify Service Action (Front and Rear) and Rear PS failure LED are NOT lit.
PARTS NOTE:
REFERENCE INFORMATION:Sun Server X2-4 Service Manual
http://docs.oracle.com/cd/E20781_01/pdf/E20784.pdf
Attachments
This solution has no attachment