Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1473762.1
Update Date:2017-06-28
Keywords:

Solution Type  Technical Instruction Sure

Solution  1473762.1 :   SL150 - How to Remove/Replace a Power Supply CRU on the StorageTek SL150 Modular Tape Library [VCAP]  


Related Items
  • StorageTek SL150 Modular Tape Library
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: TAPE-CAP VCAP
  •  
  • Microlearning>Video>ML-VID-VCAP
  •  




In this Document
Goal
Solution


Applies to:

StorageTek SL150 Modular Tape Library - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

A video procedure on how to Remove/Replace a Power Supply CRU on the StorageTek SL150 Modular Tape Library

Solution

 DISPATCH INSTRUCTIONS
   WHAT SKILLS ARE REQUIRED?: No special skills required, Customer Replaceable Unit (CRU) procedure
   TIME ESTIMATE: 60 minutes
   TASK COMPLEXITY: 0


REMOVAL/REPLACEMENT INSTRUCTIONS:
   PROBLEM OVERVIEW: How to Remove/Replace a Power Supply CRU on the StorageTek SL150 Modular Tape Library
   WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?: The SL150 library should be put into an offline state from the Web GUI
   WHAT ACTIONS ARE REQUIRED?:

Note: If the failed power supply is the only power supply in the module then the SL150 library will need to be powered down from the Web GUI in order to replace the power supply if there are redundant power supplies then the SL150 will not need to be powered down to swap out the failed power supply CRU.

Please reference the attached video for a step by step procedure on how to remove/replace the power supply CRU in the SL150 library.

To Remove the Power Supply:

1.Disconnect the power cord from the defective power supply.
2.Press the latch to the left (toward the fan) to release the power supply.
3.Grasp the power supply handle, pull the supply out of the library, and set it aside.

To Replace the Power Supply:

1.Remove the power supply from the package.
2.Grasp the power supply handle.
3.Insert the power supply into the module slot:
   a.Position the power supply with the power receptacle to the right.

   b. Align the rear of the supply with the module slot.
   c. Push the supply fully into the module slot.

4.Make sure the power supply is securely latched into the module slot.
5.Connect the power cord to the power supply.

Note: if this was the only power supply you will need to now power on the SL150 library.

6.Verify that the OK indicator illuminates on the power supply.

   WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE?: The SL150 will need to be brought to an online state from the Web GUI.

PARTS NOTE:

REFERENCE INFORMATION: Please reference the attached video for a step by step procedure on how to remove/replace the power supply CRU in the SL150 library.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.