Asset ID: |
1-71-1473686.1 |
Update Date: | 2018-01-03 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1473686.1
:
Tape - How To Determine Manufacturer of a Vendor Device by the WWN (World Wide Name)
Related Items |
- Sun StorageTek T10000 Tape Drive
- Sun StorageTek 9840 Tape Drive
- Sun StorageTek SL3000 Modular Library System
- Sun StorageTek SL500 Modular Library System
- Sun StorageTek 9940 Tape Drive
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: Tape Library Control Software
|
How to determine the company manufacturer from a WWN
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Internal Information
Applies to:
Sun StorageTek SL3000 Modular Library System - Version All Versions to All Versions [Release All Releases]
Sun StorageTek SL500 Modular Library System - Version All Versions to All Versions [Release All Releases]
Sun StorageTek T10000 Tape Drive - Version Not Applicable to Not Applicable [Release N/A]
Sun StorageTek 9840 Tape Drive - Version Not Applicable to Not Applicable [Release N/A]
Sun StorageTek 9940 Tape Drive - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.
Goal
Determine manufacturer of a vendor device by the WWN (World Wide Name)
Solution
HOW TO INTERPRET FC WWN
For Full details go to http://www.ieee.org/index.html
First Number Determines the Format:
IEEE Standard (NAA=1)
10:00 00:00:c9 22:fc:01
Section 1 Section 2 Section 3
Section 1 -> defines WWN Standard Format.
Section 2 -> company ID.
Section 3 -> unique identifier created by vendor.
IEEE Extended (NAA=2)
2 0:00 00:e0:8b 05:05:04
Section 1 Section 2 Section 3 Section 4
Section 1 -> Defines WWN as Extended Type.
Section 2 -> Is a vendor specific code and can be used to identify specific ports on a node or to extend the serial number.
Section 3 -> Vendor
Section 4 -> Unique vendor-supplied serial number for the device.
IEEE Registered Name (NAA=5)
5 0:06:04:8 1:D6:F3:45:42
Section 1 Section 2 Section 3
Section 1 -> Identifies this as a registered name WWN.
Section 2 -> Identifies the vendor.
Section 3 -> Vendor-specific generated code, usually based on the serial number of the device.
For Company IDs refer to public information IEEE
Attachments
This solution has no attachment