Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1471051.1
Update Date:2016-04-28
Keywords:

Solution Type  Technical Instruction Sure

Solution  1471051.1 :   How to Replace A/RTM for blades of Netra CT900 chassis:ATR:1471051.1:0  


Related Items
  • Sun Netra CP3270 ATCA Blade Server
  •  
  • Netra T3-1BA
  •  
  • Sun Netra CP3250 ATCA Blade Server
  •  
  • Sun Netra CT900 Server
  •  
  • Sun Netra CP3020 ATCA Blade Server
  •  
  • Sun Netra CP3260 ATCA Blade Server
  •  
  • Sun Netra CP3140 1GbE Switch
  •  
  • Sun Netra CP3240 10GbE Switch
  •  
  • Sun Netra CP3220 ATCA Blade Server
  •  
  • Sun Netra CP3010 Blade Server
  •  
  • Sun Netra CP3060 ATCA Blade Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
Goal
Solution


Applies to:

Sun Netra CP3020 ATCA Blade Server - Version Not Applicable and later
Sun Netra CP3220 ATCA Blade Server - Version Not Applicable and later
Sun Netra CP3250 ATCA Blade Server - Version Not Applicable and later
Sun Netra CP3270 ATCA Blade Server - Version Not Applicable and later
Netra T3-1BA - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How to replace a A/RTM-HD for all blade in Netra CT900 chassis

*********************************************************************
To report errors or request improvements on this procedure,
please Add a Comment on Doc ID: 1471051.1
*********************************************************************

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS ARE REQUIRED:
No special skills required, Customer Replaceable Unit (CRU) procedure

TIME ESTIMATE: 30 minutes

Task Complexity: 0

REMOVAL/REPLACEMENT INSTRUCTIONS

PROBLEM OVERVIEW: A/RTM related problem

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

DAMAGE ALERT: Perform a visual inspection of the replacement part to make sure that there are no damaged components, connectors, bent pins, damaged packages during shipping, etc. If the part is damaged, don't install it into the system, order a new part. Handle with caution and package carefully the return part to avoid any damages during shipping.


The customer might need to conduct an orderly blade shutdown using "[clia] deactivate <slot #>" command from ShMM as some configuration connects to external disk array via A/RTM


WHAT ACTIONS ARE REQUIRED:

0) Preparation --- performed by customer

1.  Lable cables conneting to A/RTM appropriately
2.  Orderly shutdown blade, if necessary

1) Remove A/RTM

0.  Verify that you have taken necessary antistatic precautions
1.  Power off the A/RTM using "[clia] deactivate <addr of slot> <FRU #>" from ShMM
2.  Remove all connected cables
3.  Loosen the locking screws on the RTM
4.  Unlatch the top and bottom latches and pull RTM out of the card slot
5.  If the card slot is to remain empty, install a filler panel in the slot
6.  Pull out the node blade in the front of the chass about 1"

2) Install A/RTM

0.  Verify that you have taken necessary antistatic precautions
1.  Go to the rear of the system and choose an appropriate slot for the rear transition module
2.  Remove the slot filler panel from the selected node board slot, if necessary
3.  Prepare the module by loosening the locking screws and opening the injector/ejector latches at the top and bottom of the module
4.  Carefully align the edges of the module with the guides in the appropriate slot
5.  Taking care to keep the module aligned in the guides, slide the module in until the injector/ejector mechanisms engage
6.  Simultaneously push in the module and push the injector/ejector mechanisms inward to their closed positions to seat the midplane connectors
7.  Tighten the RTM locking screws to ensure that the RTM is secured into the shelf
8.  Install the node board into the front of the chassis and push the board toward the midplane. Ensure that it is seated properly and that the connectors make good contact with the RTM
9.  Connect all the cables back
10. Power on the node blade, if necessary


OBTAIN CUSTOMER ACCEPTANCE


WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

1. Check all interfaces via A/RTM are up and running
2. If connecting to external network devices, verify using "ping", "traceroute", or etc commands
3. If connecting to external disk array, verify the accessibility of array


PARTS NOTE:


Netra CT900: https://support.oracle.com/handbook_private/Systems/Netra_CT_900/Netra_CT_900.html

Rear Transition Module HDD: https://support.oracle.com/handbook_private/Devices/System_Board/SYSBD_Rear_Trans_HDD_Module.html


    501-7068    Rear Transition Module
    501-7682    Rear Transition Module
    375-3283    Network Switch Rear Transition Module/FRU
    375-3508    1Gbit Network Switch Rear Transition Module FRU
    375-3512    10Gbit Ethernet Optical SFP+ Rear Transition Module
    375-3513    10Gbit/1Gbit Copper CX4 Rear Transition Module
    375-3514    Fibre Channel/Ethernet Advanced Rear Transition Module
    375-3544    10Gbit Ethernet Advanced Rear Transition Module


REFERENCE INFORMATION:

Netra CP30X0 Rear Transition Module User's Guide: http://docs.oracle.com/cd/E19490-01/819-1187-11/819-1187-11.pdf

Sun Netra CP3060 Rear Transition Module User's Guide: http://docs.oracle.com/cd/E19765-01/819-6689-10/819-6689-10.pdf

Netra CP32x0 10GbE ARTM, Dual Port Fibre channel, ARTM User's Guide: http://download.oracle.com/docs/cd/E19175-01/820-3148-10/ix.html

 