SL8500 - RE Upgrade - Must Inspect EM Cardcage
Related Items |
- Sun StorageTek SL8500 Modular Library System
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential to Service Personnel Only
Applies to:
Sun StorageTek SL8500 Modular Library System - Version Not Applicable and later
Information in this document applies to any platform.
Goal
RE Upgrade - Must Inspect EM (Electronic Module) Cardcage.
Solution
Prior to installing the RE (Redundent Electronics) feature you MUST carefully inspect the cardcage pins that will be engaging the new HBT and HBCR cards on the "B" side. It is recommended that these pins be inspected prior to the scheduled upgrade to insure there is ample time to acquire a replacement cardcage if necessary (PN 419802701). There has been a high rate of bent pins while installing the RE cards and care must be exercised during the installation.