Asset ID: |
1-71-1464540.1 |
Update Date: | 2016-03-11 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1464540.1
:
How to Replace a Netra T5220 DVD drive:ATR:1464540.1:0
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
Applies to:
Sun Netra T5220 Server - Version All Versions and later
Information in this document applies to any platform.
Goal
How to Replace a Netra T5220 DVD Drive
***************************************************************************************
To report errors or request improvements on this procedure, please add a comment on Doc ID: 1464540.1
***************************************************************************************
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS ARE REQUIRED?: No special skills required, Customer Replaceable Unit (CRU) procedure
TIME ESTIMATE: 60 minutes
Task Complexity: 0
REMOVAL/REPLACEMENT INSTRUCTIONS:
PROBLEM OVERVIEW: Faulty DVD Drive
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
A data backup is not a pre-requisite but is a wise precaution.
Customer should shut the operating system down gracefully (using "init 0"), and after the system has shut down Switch from the system console to the -> prompt by typing the #. (Hash Period) key sequence. At the -> prompt, type the stop /SYS command.
WHAT ACTIONS ARE REQUIRED?:
*** Follow standard ESD procedures to avoid Electrostatic Discharge
1. Disconnect all power cables
Removal:
1. Move the left DVD locking arm to the left & then remove the DVD drive.
Installation:
1. Install DVD drive, BUT ensure that the new drive is the same type/part number as the prior since this platform initially released with a PATA DVD, but then transitioned to using a SATA DVD toward the end of production. PATA & SATA drives are not compatible & require a differing PDB.
2. Connect all power cables.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE?:
Customer restart software applications per applicable administration guides to resume system operation.
PARTS NOTE: https://support.oracle.com/handbook_private/Systems/Netra_T5220/components.html#RemovableMedia
REFERENCE INFORMATION: http://docs.oracle.com/cd/E19350-01/index.html
Attachments