Solution Type  Technical Instruction Sure

Solution  1464513.1 :   How to Replace a Netra T5220 Media Bay Assembly  


Related Items
  • Sun Netra T5220 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU

Applies to:

Sun Netra T5220 Server - Version All Versions and later
Information in this document applies to any platform.

Goal

This document provides the procedure on how to Replace a Netra T5220 Media Bay Assembly

**************************************************************************************
To report errors or request improvements on this procedure, please add a comment on Doc ID: 1464513.1
**************************************************************************************

Solution

DISPATCH INSTRUCTIONS


WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
T5220 Product Knowledge or Training

TIME ESTIMATE: 60 minutes

Task Complexity: 1

REMOVAL/REPLACEMENT INSTRUCTIONS:

PROBLEM OVERVIEW: Faulty Disk Backplane

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
A data backup is not a pre-requisite but is a wise precaution.
Customer should shut the operating system down gracefully (using "init 0"), and after the system has shut down Switch from the system console to the -> prompt by typing the #. (Hash Period) key sequence. At the -> prompt, type the stop /SYS command.

WHAT ACTIONS ARE REQUIRED?:

*** Follow standard ESD procedures to avoid Electrostatic Discharge

1. Disconnect all power cables
2. Remove the Top Cover

Removal:

1. Remove the hard drives &  DVD if one installed.  Please note the location of the hard drives so that they a installed in the same position on the new assembly.

2. Disconnect the cables from the media assembly.

3. Untighten the captive Green screws & then remove the media assembly.


Installation:

1. Insert the media assembly & tighten the green captive screws.

2. Connect the cables to the media assembly.

3. Install the hard drives & DVD drive (if one installed prior).

4. Install Top Cover.

5. Connect all power cables.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE?:

Customer restart software applications per applicable administration guides to resume system operation.

PARTS NOTE:  https://support.oracle.com/handbook_private/Systems/Netra_T5220/components.html#DiskBackplane

REFERENCE INFORMATION:   http://docs.oracle.com/cd/E19350-01/index.html


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback