How to Replace a Netra T5220 Media Bay Assembly
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU
Applies to:
Sun Netra T5220 Server - Version All Versions and later
Information in this document applies to any platform.
Goal
This document provides the procedure on how to Replace a Netra T5220 Media Bay Assembly
**************************************************************************************
To report errors or request improvements on this procedure, please add a comment on Doc ID: 1464513.1
**************************************************************************************
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
T5220 Product Knowledge or Training
TIME ESTIMATE: 60 minutes
Task Complexity: 1
REMOVAL/REPLACEMENT INSTRUCTIONS:
PROBLEM OVERVIEW: Faulty Disk Backplane
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
A data backup is not a pre-requisite but is a wise precaution.
Customer should shut the operating system down gracefully (using "init 0"), and after the system has shut down Switch from the system console to the -> prompt by typing the #. (Hash Period) key sequence. At the -> prompt, type the stop /SYS command.
WHAT ACTIONS ARE REQUIRED?:
*** Follow standard ESD procedures to avoid Electrostatic Discharge
1. Disconnect all power cables
2. Remove the Top Cover
Removal:
1. Remove the hard drives & DVD if one installed. Please note the location of the hard drives so that they a installed in the same position on the new assembly.
2. Disconnect the cables from the media assembly.
3. Untighten the captive Green screws & then remove the media assembly.
Installation:
1. Insert the media assembly & tighten the green captive screws.
2. Connect the cables to the media assembly.
3. Install the hard drives & DVD drive (if one installed prior).
4. Install Top Cover.
5. Connect all power cables.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE?:
Customer restart software applications per applicable administration guides to resume system operation.
PARTS NOTE: https://support.oracle.com/handbook_private/Systems/Netra_T5220/components.html#DiskBackplane