Solution Type Technical Instruction Sure Solution 1464127.1 : How to replace a Netra T5440 SAS Expander Board:ATR:1464127.1:0
Applies to:Sun Netra T5440 Server - Version All Versions and laterInformation in this document applies to any platform. GoalHow to replace a Netra T5440 SAS Expander Board *************************************************************************************** SolutionDISPATCH INSTRUCTIONS WHAT ACTIONS ARE REQUIRED?: Remove the SAS Expander Board: 1. Remove the top cover, 2. Remove Fan Tray 1. 3. Remove PCI cards in slots 1-4, & note their positions & external cabling. 4. Remove the SAS Expander board (make note of the SAS cable connection).
Install the SAS Expander Board: 1. Install the SAS Expander board & place the SAS cable in its original position. 2. Install the PCI cards into Slots 1-4 in their original position with original cables. 3. Install Fan Tray 1. 4. Install the top cover.
OBTAIN CUSTOMER ACCEPTANCE