Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1462987.1
Update Date:2016-03-14
Keywords:

Solution Type  Technical Instruction Sure

Solution  1462987.1 :   How to Replace a Netra T5440 Battery Module:ATR:1462987.1:0  


Related Items
  • Sun Netra T5440 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




Applies to:

Sun Netra T5440 Server - Version All Versions and later
Information in this document applies to any platform.

Goal

How to replace a Netra T5440 Battery Module

***************************************************************************************
To report errors or request improvements on this procedure, please Add a Comment on Doc ID: 1462987.1
***************************************************************************************

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS ARE REQUIRED?: No special skills required, Customer Replaceable Unit (CRU) procedure

TIME ESTIMATE: 30 minutes

Task Complexity: 0

REMOVAL/REPLACEMENT INSTRUCTIONS:

PROBLEM OVERVIEW:  Defective battery module

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?
A data backup is not a pre-requisite but is a wise precaution.
System needs to be shutdown by customer

WHAT ACTIONS ARE REQUIRED?:
*** Follow standard ESD procedures to avoid Electrostatic Discharge

A) Remove Battery

1. Remove the Top Cover

2. Remove the PCI Mezzanine Assembly

3. Gently depress the release tab and pull the battery out of the battery housing


B) Install Battery

1. Carefully press the new battery in the slot

2. Install the PCI Mezzanine Assembly

3. Install the Top Cover


OBTAIN CUSTOMER ACCEPTANCE:

WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE?:
Verify functionality, no service LEDs or messages.

PARTS NOTES:    https://support.oracle.com/handbook_private/Systems/Netra_T5440/components.html#SystemBoard