1462382.1
:
How to Remove and Replace a SPARC T6320 RAID Expansion Module:ATR:1462382.1:0
Related Items |
- Sun Blade 6048 System
- Sun Blade T6320 Server Module
- Sun Blade 6000 System
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
In this Document
Applies to:
Sun Blade 6048 System - Version All Versions and later
Sun Blade T6320 Server Module - Version All Versions and later
Sun Blade 6000 System - Version All Versions and later
Information in this document applies to any platform.
Goal
How to Remove and Replace a SPARC T6320 RAID Expansion Module
********************************************************************************
To report errors or request improvements on this procedure,
please Add a Comment on Doc ID: 1462382.1
********************************************************************************
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS ARE REQUIRED:
No special skills required, Customer Replaceable Unit (CRU) procedure
TIME ESTIMATE: 30 minutes
TASK COMPLEXITY: 0
REMOVAL/REPLACEMENT INSTRUCTIONS
PROBLEM OVERVIEW: failed RAID Expansion Module (REM)
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
Note: If T6320 is connected to a Disk Module, save the configuration before removing it.
Refer to the Sun Blade 6000 Disk Module Service Manual, http://docs.oracle.com/cd/E19045-01/blade.6000disk/820-1703-13/index.html
and the Sun Blade 6000 Disk Module Administration Guide http://docs.oracle.com/cd/E19045-01/blade.6000disk/820-4922-16/index.html
Note: After replacing the RAID controller (REM), any existing HW RAID volumes (and member disks) may not be seen and need to be re-activated. If the Disk Volumes (including boot volume/disk) become inaccessible, consult: Troubleshooting inability to see a pre-existing RAID volume on T1000/T2000 T5120/T5140/T5220/T5240/T5440 T6320/T6340 (Doc ID 1009723.1)
Shut Down the Oracle Solaris OS
Prepare the Server Module for Removal
Remove the Server Module From the Modular System
Remove the Cover
ESD Safety Measures
WHAT ACTIONS ARE REQUIRED:
Remove a REM
1. Place your fingers under the RAID expansion module (REM), with each finger close top the connector.
2. Lift the card free from the connector.
3. Lift the REM free from the gray plastic standoff.
Install a REM
1. Place the card under the tabs of the gray plastic standoff.
2. Press on the rubber button on the top of the card until the connector engages with the connector on the motherboard.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Boot system and monitor boot sequence for errors. Test functionality of system:
1. Run the Solaris "fmadm faulty" and SP/ILOM "show faulty" command (if only ALOM is supported run "showfaults -v" command) to verify that the fault has been cleared.
2. Perform one of the following tasks based on your verification results:
* If the previous steps did not clear the fault, refer to doc 1004229.1 for information about the tools and methods you can use to diagnose and clear
component faults.
* If the previous steps indicate that no faults have been detected, the component has been replaced successfully. No further action is required
3. Restart software applications per applicable administration guides to resume system operation.
PARTS NOTE:
https://support.oracle.com/handbook_private/Systems/SunBladeT6320/components.html#SCSI
REFERENCE INFORMATION:
SPARC T6320 Server Module Service Manual at http://docs.oracle.com/cd/E19745-01/820-2386-12/index.html