Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1461948.1
Update Date:2017-10-18
Keywords:

Solution Type  Technical Instruction Sure

Solution  1461948.1 :   How to Replace an Internal Tape Drive for Sun Fire V1280/E2900 and Netra 1280/1290:ATR:1461948.1:2  


Related Items
  • Sun Fire E2900 Server
  •  
  • Sun Fire V1280 Server
  •  
  • Sun Netra 1280 Server
  •  
  • Sun Netra 1290 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
Goal
Fix


Oracle Confidential (INTERNAL). Do not distribute to customers.
Reason: Part is a FRU

Applies to:

Sun Fire V1280 Server - Version Not Applicable to Not Applicable [Release N/A]
Sun Netra 1280 Server - Version Not Applicable to Not Applicable [Release N/A]
Sun Netra 1290 Server - Version Not Applicable to Not Applicable [Release N/A]
Sun Fire E2900 Server - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Goal

 ******************************************************************************
To report errors or request improvements on this procedure,
please go to http://support.us.oracle.com and put a comment on Doc ID
: 1461948.1
******************************************************************************

Fix

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
Engineer should be LW8 product trained

TIME ESTIMATE: 60 minutes

TASK COMPLEXITY: 2


FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS

PROBLEM OVERVIEW:
How to replace a Tape Drive

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

Take the system to Standby mode by typing the shutdown command at the lom>prompt.


WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

1.  Take the system to Standby mode.
2.  Open the right front door of the system.
3.  Attach a wrist strap. Place a grounded ESD mat close to the system.
4.  Hold the metal tab located on the left of the tape drive. Remove the tape drive.
5.  Place the tape drive on an ESD mat.
6.  If you are not installing a replacement tape drive at this time, install a filler panel.
7.  Remove the four screws securing the baseplate to the drive you removed. Remove the baseplate
8.  Attach the baseplate to the new tape drive. Use the four countersunk screws shipped with the drive
9.  Install the new drive. Insert it into the system until the metal latch on the left side engages.
10. Detach the antistatic wrist strap.
11. Close the front door of the system.
12. Power on the system.

 


WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

Verify the Operating system is operational

Restart the applications