Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1461220.1
Update Date:2017-01-12
Keywords:

Solution Type  Technical Instruction Sure

Solution  1461220.1 :   How to Remove and Replace a SPARC T4-1B or Netra T4-1B System Battery:ATR:1461220.1:0  


Related Items
  • Sun Blade 6000 System
  •  
  • Netra SPARC T4-1B
  •  
  • SPARC T4-1B
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
Goal
Solution


Applies to:

SPARC T4-1B - Version All Versions and later
Sun Blade 6000 System - Version All Versions and later
Netra SPARC T4-1B - Version All Versions and later
Information in this document applies to any platform.

Goal

How to Remove and Replace a SPARC T4-1B & Netra SPARC T4-1B System Battery

********************************************************************************
To report errors or request improvements on this procedure,
please Add a Comment on Doc ID: 1461220.1
********************************************************************************

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS ARE REQUIRED?: No special skills required, Customer Replaceable Unit (CRU) procedure

TIME ESTIMATE: 30 minutes

TASK COMPLEXITY: 0

REMOVAL/REPLACEMENT INSTRUCTIONS:

PROBLEM OVERVIEW: failed SPARC T4-1B/Netra SPARC T4-1B system battery

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

DAMAGE ALERT: Perform a visual inspection of the replacement part to make sure that there are no damaged components, connectors, bent pins, damaged packages during shipping, etc. If the part is damaged, don't install it into the system, order a new part. Handle with caution and package carefully the return part to avoid any damages during shipping.


Prepare for service by performing the following tasks:

    Shut Down the Oracle Solaris OS
    Prepare the Server Module for Removal
    Remove the Server Module From the Modular System
    Remove the Cover
    ESD Safety Measures

WHAT ACTIONS ARE REQUIRED?:

1. If you need more clearance, remove the DIMM in slot CMP0/BOB3/CH1/D0 (nearest the battery).

2. Push the top of the battery forward, then lift the battery from the holder

3. Install the replacement battery with the negative (-) side facing the nearby DIMM slot CMP0/BOB3/CH1/D0.

4. (If removed) Replace the DIMM in CMP0/BOB3/CH1/D0.

5. Return the server module to operation.

6. Use an Oracle ILOM command to set the clock’s day and time.

For example:

-> set /SP/clock datetime=061716192012
-> show /SP/clock

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE?::
Boot system and monitor boot sequence for errors. Test functionality of system. Restart software applications per applicable administration guides to resume system operation.

PARTS NOTE:
https://support.oracle.com/handbook_private/Systems/SPARC_T4_1B/components.html#Batteries

https://support.oracle.com/handbook_private/Systems/Netra_T4_1B/components.html



REFERENCE INFORMATION:
SPARC T4-1B Server Module Service Manual: http://docs.oracle.com/cd/E22735_01/pdf/E22739.pdf

Netra SPARC T4-1B Server Module Service Manual: http://docs.oracle.com/cd/E25041_01/pdf/E25046.pdf

 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback