Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1460805.1
Update Date:2016-04-25
Keywords:

Solution Type  Technical Instruction Sure

Solution  1460805.1 :   How to Replace a Netra T4-2 Front Fans:ATR:1460805.1:0  


Related Items
  • Netra SPARC T4-2 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




Applies to:

Netra SPARC T4-2 Server - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How to Replace a Netra T4-2 Front Fan

********************************************************************************
To report errors or request improvements on this procedure, please put a comment on Doc ID: 1460805.1
********************************************************************************

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS ARE REQUIRED: No special skills required, Customer Replaceable Unit (CRU) procedure

Time Estimate: 30 minutes

Task Complexity: 0

REMOVAL/REPLACEMENT INSTRUCTIONS

PROBLEM OVERVIEW: fan module failure

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

DAMAGE ALERT: Perform a visual inspection of the replacement part to make sure that there are no damaged components, connectors, bent pins, damaged packages during shipping, etc. If the part is damaged, don't install it into the system, order a new part. Handle with caution and package carefully the return part to avoid any damages during shipping.

 
The fan module is a Hot Swappable CRU. The 4 fan modules in the server are located at the front of the chassis.

WHAT ACTIONS ARE REQUIRED:

CAUTION - While the fan modules provide some cooling redundancy, if a fan module fails, replace it as soon as possible to maintain server availability. When you remove one of the fans in the rear row, you must replace it within 30 seconds to prevent overheating of the server.

A) Locate a Faulty Fan Module

View the following LEDs, which are lit when a fan module fault is detected:
- Fan Module (FAN) Fault LED on the front of the server.
Each fan module contains an LED. When the amber Service Required LED is lit, a fault has occurred on that fan module.


B) Removing a Fan Module

1. Press down on the two latches to release the filter tray from the chassis.

2. Flip the filter tray over to access the air filter.

3. Remove the filter tray.

4. Determine which fan module to remove.

5. Pinch the lever release buttons at the bottom of the fan module.

6. Pull the release lever out and up.

7. Pull the fan module out from the chassis by the lever.


C) Install a Fan Module

1. Lift the lever to the raised position and align the fan module to the location where it installs into the chassis.

2. Push the fan module into the chassis until the lever moves slightly down.

3. Lower the lever down to secure the fan module into the chassis.

4. Push on the release lever so that it clicks.

5. Install the filter tray

6. Close the filter tray


OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

Verify Service Processor Functionality

PARTS NOTE:
refer to:  https://support.oracle.com/handbook_private/Systems/Netra_T4_2/components.html#Fan

REFERENCE INFORMATION:
Netra T4-2 Service Manual  http://docs.oracle.com/cd/E21893_01/index.html


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.