Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1458845.1
Update Date:2016-04-20
Keywords:

Solution Type  Technical Instruction Sure

Solution  1458845.1 :   How To Replace a Netra T3-1/T4-1 LED board:ATR:1458845.1:0  


Related Items
  • Netra SPARC T4-1 Server
  •  
  • Netra T3-1
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




Applies to:

Netra T3-1 - Version All Versions and later
Netra SPARC T4-1 Server - Version All Versions and later
Information in this document applies to any platform.

Goal

Service the LED board

********************************************************************************
To report errors or request improvements on this procedure, please put a comment on Doc ID: 1458845.1
********************************************************************************

Solution

 DISPATCH INSTRUCTIONS

WHAT SKILLS ARE REQUIRED?:  No special skills required, Customer Replaceable Unit (CRU) procedure

TIME ESTIMATE: 30 minutes

TASK COMPLEXITY: 0

REMOVAL/REPLACEMENT INSTRUCTIONS

PROBLEM OVERVIEW: LED board failure

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

DAMAGE ALERT: Perform a visual inspection of the replacement part to make sure that there are no damaged components, connectors, bent pins, damaged packages during shipping, etc. If the part is damaged, don't install it into the system, order a new part. Handle with caution and package carefully the return part to avoid any damages during shipping.

Shut down system and Power down the server.

WHAT ACTIONS ARE REQUIRED:


A. Remove LED board:

1. Remove top cover.

2. Remove the DVD tray.

3. Remove the fan board.

4. Remove the six screws that secure the LED board to the DVD tray

5. Lift the LED board away from the DVD tray and set the LED board aside.


B. Install LED board:

1. Align the LED board to the location where it installs onto the DVD tray.  The LEDs are the front of the bracket.

2. Secure the LED board to the DVD tray with the six screws.

3. Install the fan board.

4. Install the DVD tray.

5. Install the top cover


OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Turn on the system and verify functionality.

PARTS NOTE: 542-0391 [C]  DVD Tray Assembly  (same part on Netra T3 & T4)

https://support.oracle.com/handbook_private/Systems/Netra_T3_1/components.html#I/O

https://support.oracle.com/handbook_private/Systems/Netra_T4_1/components.html#I/O



REFERENCE INFORMATION: Netra SPARC T3-1 Service Manual, p/n E20693-xx 

or Netra SPARC T4-1 Service Manual, p/n E23206-xx


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback