Goal
Service Fan Module
**********************************************************************************
To report errors or request improvements on this procedure, please Add a Comment on Doc ID: 1458521.1
**********************************************************************************
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS ARE REQUIRED?: No special skills required, Customer Replaceable Unit (CRU) procedure
Time Estimate: 20 minutes
Task Complexity: 0
REMOVAL/REPLACEMENT INSTRUCTIONS
PROBLEM OVERVIEW: Fan failure
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
DAMAGE ALERT: Perform a visual inspection of the replacement part to make sure that there are no damaged components, connectors, bent pins, damaged packages during shipping, etc. If the part is damaged, don't install it into the system, order a new part. Handle with caution and package carefully the return part to avoid any damages during shipping.
WHAT ACTIONS ARE REQUIRED:
Take ESD Precautions
A. Remove a Fan Module
1. Check the front or rear panel System Fault LED. A fan fault will cause the System Fault LED (on front and rear of server) as well as a Fan Fault LED in the array of fan status LEDs to be lighted. If the color of a Fan Fault LED is amber, replace the corresponding fan module.
2. Remove the filter tray.
3. Grasp the lever at the top of the fan module and move the lever to the left
4. Pull the fan module out from the chassis by the lever
B. Install a Fan Module
1. Align the fan module to the location where it installs into the chassis. The lever is on the top front of the fan module, the connector is on the top rear.
2. Move the lever to the left and slide the fan module into the chassis
3. Push the fan module into the chassis until the lever moves slightly to the right.
4. Move the lever to the right to fully seat the fan module into the chassis.
5. Install the filter tray.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Verify functionality, no service LEDs or messages
PARTS NOTE: 351-0011 [C] Dual System Fan FM0-FM4 (same part for both the Netra T3-1 & T4-1)
https://support.oracle.com/handbook_private/Systems/Netra_T4_1/components.html#Fan