Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1449803.1
Update Date:2017-11-30
Keywords:

Solution Type  Technical Instruction Sure

Solution  1449803.1 :   How to Replace Netra 240 Air Duct and Rear Fan Assembly:ATR:1449803.1:0  


Related Items
  • Sun Netra 240 (DC) Server
  •  
  • Sun Netra 240 (AC) Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
Goal
Solution


Applies to:

Sun Netra 240 (AC) Server - Version Not Applicable and later
Sun Netra 240 (DC) Server - Version Not Applicable and later
Information in this document applies to any platform.

Goal

This document provides the procedure on how to replace the Netra 240 Air Duct and Rear Fan Assembly

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS ARE REQUIRED:
No special skills required, Customer Replaceable Unit (CRU) procedure

TASK COMPLEXITY: 0

TIME ESTIMATE: 150 minutes

REMOVAL/REPLACEMENT INSTRUCTIONS

PROBLEM OVERVIEW: Air Duct and Rear Fan Assembly

OBTAIN CUSTOMER ACCEPTANCE
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.

WHAT ACTIONS ARE REQUIRED:

The air duct and rear fan assembly contains two fans, F0 and F1. The entire rear fan assembly should be replaced if one of these fans fail.

Removing or Rotating the Air Duct and Rear Fan Assembly

1.Power off the server.

2.Remove the server cover.

3.Open the rotating service module.

4.Ensure that the server is properly grounded.

5.Determine if you want to gain access to the components beneath the air duct and rear fan assembly, or if you want to completely remove the assembly from the server

■If you want to gain access to components beneath the air duct and rear fan assembly, push the tab on the right of the assembly to the rear of the system, then rotate it up and out of the way.
■If you want to completely remove the air duct and rear fan assembly from the server:
a.Push the tab on the right of the assembly to the rear of the assembly and rotate the assembly up.
b. Unplug the two lower cables from the system board.
c. Dislodge the assembly from the rear supports and slide it out of the system.

Installing or Closing the Air Duct and Rear Fan Assembly

1.Slide the air duct and rear fan assembly into position.

2.Plug in the two lower cables from the system board

3.Rotate the assembly back in position and press down to snap the locking tab.

4.Close the rotating service module.

5.Install the server cover.

6.Power on the server.

WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

Restart software applications per applicable administration guides to resume system operation.

PARTS NOTE: Include Air Duct and Rear Fan Assembly location

https://support.oracle.com/handbook_private/Systems/Netra_240/components.html#Fan

https://support.oracle.com/handbook_private/Systems/Netra_240_R/components.html#Fan


ADDITIONAL COMMENTS:

Please refer to the Netra 240 Server Service Manual: http://docs.oracle.com/cd/E19102-01/n240.srvr/817-2699-13/817-2699-13.pdf


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback