Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1446920.1
Update Date:2014-03-20
Keywords:

Solution Type  Technical Instruction Sure

Solution  1446920.1 :   How to Remove and Replace a System Board in a Sun Netra X4270  


Related Items
  • Sun Netra X4270 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




In this Document
Goal
Solution
References


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP

Applies to:

Sun Netra X4270 Server - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How to Remove and Replace a Sun Netra X4270 System Board

Solution

 DISPATCH INSTRUCTIONS

- WHAT SKILLS DOES THE ENGINEER NEED:

WZT-6511: Sun Fire Nehalem-Based Rack Mount Servers Troubleshooting



- TIME ESTIMATE: 60 minutes

- TASK COMPLEXITY: 3



FIELD ENGINEER INSTRUCTIONS:

- PROBLEM OVERVIEW:Failed system board (motherboard) assembly

- WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE

RESOLUTION ACTIVITY?:

Shut down system and Power down the server.



- WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

Follow standard ESD procedures

1. Power off the server and unplug (REMOVE) the power cords from power supplies

2. Remove the top cover

3. For Netra X4270 remove the plastic air baffle

4. Disconnect the storage drive data cables from the SAS PCIe card or the motherboard SATA connectors

5. Remove the memory dimms from the motherboard

6. Remove the PCIe risers and PCIe cards from the motherboard

7. Remove the CPU modules from the motherboard

8. Remove the compact flash card

9. Disconnect the power distribution board ribbon cable

10. Remove the four screws that hold the motherboard to the bus bar

11. Loosen the green captive screw on the front of the motherboard that secure it to the chassis

12. Carefully slide the motherboard to the back of the chassis and lift out using the finger loop which is below the four screws that hold the motherboard to the bus bar.

13. Carefully install the replacement motherboard into the chassis and push to the front of the chassis

14. Insert the four screws that secure the motherboard to the bus bar

15. Tighten the green captive on the front of the motherboard to secure it to the chassis

16. Re-install the memory dimms

17. Re-install the CPU modules

18. Re-install the compact flash card

19. Re-install the PCIe risers and PCIe cards

20. Re-connect the power distribution board ribbon cable to the motherboard

21. Connect the storage drive data cables to the the storage drive cage

22. For Netra X4270 re-install the air baffle

23. Replace the top/main cover

24. Re-connect the power cords

25. Re-program serial number into FRUID

26. Update ILOM to latest version.



OBTAIN CUSTOMER ACCEPTANCE

- WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO

AN OPERATIONAL STATE:

Boot up system and verify full functionality





PARTS NOTE: Ensure the socket covers are installed on the old motherboard before packaging.

Document any socket damage observed on the return tag.





REFERENCE INFORMATION:



Sun Netra X4270 Server Service Manual





http://docs.oracle.com/cd/E19591-01/E23171/E23171.pdf

References

<NOTE:1019946.1> - How to access service mode and escalation mode on ILOM 3.x and later platforms
<NOTE:1378047.1> - How to Reprogram the Server Serial Number on the Sun Fire X4170, x4270, X4275:ATR:1378047.1:2

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback