Asset ID: |
1-71-1444737.1 |
Update Date: | 2017-01-12 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1444737.1
:
How to Remove and Replace a SPARC T3-1B & Netra SPARC T3-1B Fabric Expansion Module:ATR:1444737.1:0
Related Items |
- SPARC T3-1B
- Netra SPARC T3-1B
- Sun Blade 6000 System
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
In this Document
Applies to:
SPARC T3-1B - Version All Versions and later
Sun Blade 6000 System - Version All Versions and later
Netra SPARC T3-1B - Version All Versions and later
Information in this document applies to any platform.
Goal
How to Remove and Replace a SPARC/NETRA T3-1B Fabric Expansion Module
****************************************************************
To report errors or request improvements on this procedure,
please Add a Comment on Doc ID: 1444737.1
****************************************************************
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS ARE REQUIRED:
No special skills required, Customer Replaceable Unit (CRU) procedure
TIME ESTIMATE: 30 minutes
TASK COMPLEXITY: 0
REMOVAL/REPLACEMENT INSTRUCTIONS
PPOBLEM OVERVIEW: failed FEM
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
DAMAGE ALERT: Perform a visual inspection of the replacement part to make sure that there are no damaged components, connectors, bent pins, damaged packages during shipping, etc. If the part is damaged, don't install it into the system, order a new part. Handle with caution and package carefully the return part to avoid any damages during shipping.
Shut Down the Oracle Solaris OS
Prepare the Server Module for Removal
Remove the Server Module From the Modular System
Remove the Cover
ESD Safety Measures
WHAT ACTIONS ARE REQUIRED:
Remove a FEM
1. Lift the lever to eject the card.
2. Rotate the card up and off the retainer.
3. Place the removed FEM on an antistatic mat.
Install a FEM
1. Determine the correct set of motherboard FEM connectors for your FEM.
a. An L-shaped FEM uses connectors FEM-X and FEM-0.
b. A rectangular double-width FEM uses connectors FEM-0 and FEM-1.
c. A rectangular single-width FEM uses connector FEM-0.
2. Insert the FEM edge into the bracket and carefully align the FEM so that the card connects with the correct motherboard connectors.
3. Lower the card and press the card into place.
If the card has rubber bumpers you can press directly on them to seat the card into the connectors.
4. Return the server module to operation.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Boot system and monitor boot sequence for errors. Test functionality of system:
1. Run the Solaris "fmadm faulty" and SP/ILOM "show faulty" command (if only ALOM is supported run "showfaults -v" command) to verify that the fault has been cleared.
2. Perform one of the following tasks based on your verification results:
* If the previous steps did not clear the fault, refer to doc 1004229.1 for information about the tools and methods you can use to diagnose and clear
component faults.
* If the previous steps indicate that no faults have been detected, the component has been replaced successfully. No further action is required
3. Restart software applications per applicable administration guides to resume system operation.
PARTS NOTE:
https://support.oracle.com/handbook_private/Systems/SPARC_T3_1B/components.html
https://support.oracle.com/handbook_private/Systems/Netra_T3_1B/components.html
REFERENCE INFORMATION:
SPARC T3-1B Server Module Service Manual: http://docs.oracle.com/cd/E19332-01/E29280/E29280.pdf
Netra SPARC T3-1B Server Module Service Manual: http://docs.oracle.com/cd/E20658_01/index.html
Attachments