Solution Type Technical Instruction Sure Solution 1444734.1 : How to Use a SPARC T3-1B Dongle Cable Adapter
In this Document
Applies to:SPARC T3-1B - Version All Versions to All Versions [Release All Releases]Sun Blade 6000 System - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. GoalHow to Use a SPARC T3-1B Dongle Cable Adapter
SolutionNo cables are connected to the server module during normal system operation. For setup, testing, or service purposes, you can connect cables directly to the server module by first attaching a dongle cable to the UCP on the front panel of the server module. * The UCP-3 dongle cable has an RJ-45 connector. * The UCP-4 dongle cable has an RJ-45 connector, but that is not supported on this server module. Instead, use the DB-9 connector provided on the UCP-4. If you need an RJ-45 connection, attach an optional DB-9-to-RJ-45 adapter to the DB-9 connector. Attachments This solution has no attachment |
||||||||||||||
|