Asset ID: |
1-71-1443798.1 |
Update Date: | 2017-01-12 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1443798.1
:
How to Remove and Replace a SPARC T3-1B & Netra SPARC T3-1B System Battery:ATR:1443798.1:0
Related Items |
- SPARC T3-1B
- Sun Blade 6000 System
- Netra SPARC T3-1B
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
In this Document
Applies to:
SPARC T3-1B - Version All Versions and later
Sun Blade 6000 System - Version All Versions and later
Netra SPARC T3-1B - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to Remove and Replace a SPARC/NETRA T3-1B System Battery
********************************************************************************
To report errors or request improvements on this procedure,
please Add a Comment on Doc ID: 1443798.1
********************************************************************************
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS ARE REQUIRED:
No special skills required, Customer Replaceable Unit (CRU) procedure
TIME ESTIMATE: 30 minutes
TASK COMPLEXITY: 0
REMOVAL/REPLACEMENT INSTRUCTIONS
PROBLEM OVERVIEW: failed SPARC/NETRA T3-1B system battery
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
DAMAGE ALERT: Perform a visual inspection of the replacement part to make sure that there are no damaged components, connectors, bent pins, damaged packages during shipping, etc. If the part is damaged, don't install it into the system, order a new part. Handle with caution and package carefully the return part to avoid any damages during shipping.
Prepare for service by performing the following tasks:
Shut Down the Oracle Solaris OS
Prepare the Server Module for Removal
Remove the Server Module From the Modular System
Remove the Cover
ESD Safety Measures
WHAT ACTIONS ARE REQUIRED:
1. Remove a FEM card using connector FEM 1 (if present).
2. Push the top of the battery forward, then lift the battery from the holder
3. Install the replacement battery with the negative (-) side out.
4. Put the FEM back in place if you needed to remove it to access the battery.
5. Return the server module to operation.
6. Use an Oracle ILOM command to set the clock’s day and time.
For example:
-> set /SP/clock datetime=061716192010
-> show /SP/clock
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Boot system and monitor boot sequence for errors. Test functionality of system:
1. Run the Solaris "fmadm faulty" and SP/ILOM "show faulty" command (if only ALOM is supported run "showfaults -v" command) to verify that the fault has been cleared.
2. Perform one of the following tasks based on your verification results:
* If the previous steps did not clear the fault, refer to doc 1004229.1 for information about the tools and methods you can use to diagnose and clear
component faults.
* If the previous steps indicate that no faults have been detected, the component has been replaced successfully. No further action is required
3. Restart software applications per applicable administration guides to resume system operation.
PARTS NOTE:
https://support.oracle.com/handbook_private/Systems/SPARC_T3_1B/components.html
https://support.oracle.com/handbook_private/Systems/Netra_T3_1B/components.html
REFERENCE INFORMATION:
SPARC T3-1B Server Module Service Manual: http://docs.oracle.com/cd/E19332-01/E29280/E29280.pdf
Netra SPARC T3-1B Server Module Service Manual: http://docs.oracle.com/cd/E20658_01/index.html
Attachments
This solution has no attachment