![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Technical Instruction Sure Solution 1434184.1 : Sun Storage 7000 Unified Storage System: How to Troubleshoot Fibre-Channel Problems
In this Document
Applies to:Sun Storage 7310 Unified Storage System - Version All Versions and laterSun ZFS Storage 7420 - Version All Versions and later Sun Storage 7110 Unified Storage System - Version All Versions and later Sun Storage 7210 Unified Storage System - Version All Versions and later Sun Storage 7410 Unified Storage System - Version All Versions and later 7000 Appliance OS (Fishworks) GoalHow to Troubleshoot Fibre-Channel Problems on a Unified Storage SolutionThe purpose of this document is to assist in identifying, troubleshooting Refer to 1432935.1 Sun Storage 7000 Unified Storage System: How to verify host connectivity to Unified Storage Refer to 1433014.1 Sun Storage 7000 Unified Storage System: How to verify that the multipathing software (MPxIO / VxDMP) is optimal Refer to 1434004.1 Sun Storage 7000 Unified Storage System: Verifying that the Unified Storage has been configured correctly for Fibre-Channel connectivity Refer to 1434045.1 Sun Storage 7000 Unified Storage System: Verifying the Fabric health for Fibre-Channel connectivity To troubleshoot FC boot issues, please refer to Implementing Fibre Channel SAN Boot with Oracle's Sun ZFS Storage Appliance
Refer to 1434007.1 Sun Storage 7000 Unified Storage System: Troubleshooting performance problems with Fibre-Channel Luns - a Solaris[TM] Explorer (Refer to 1312847.1 Sun Explorer Product Information Center). - a support bundle after collecting analytics information (in case of performance issues). Refer to 1019887.1 Sun Storage 7000 Unified Storage System: How to collect supportfile bundle using BUI or CLI.
References<NOTE:1312847.1> - Oracle Explorer Data Collector Resource Center<NOTE:1019887.1> - Sun Storage 7000 Unified Storage System: How to Collect a Support Bundle using the BUI or CLI <NOTE:1432935.1> - Sun Storage 7000 Unified Storage System: How to verify host connectivity to Unified Storage <NOTE:1433014.1> - Sun Storage 7000 Unified Storage System: How to verify that the multipathing software ( MPxIO / VxDMP) is optimal <NOTE:1434004.1> - Sun Storage 7000 Unified Storage System: Verifying that the Unified Storage has been configured correctly for Fibre-Channel connectivity <NOTE:1434007.1> - Sun Storage 7000 Unified Storage System: Troubleshooting performance problems with Fibre-Channel LUNs <NOTE:1434045.1> - Sun Storage 7000 Unified Storage System: Verifying the Fabric health to troubleshoot Fibre-Channel connectivity Attachments This solution has no attachment |
||||||||||||||||
|