Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1434045.1
Update Date:2016-05-19
Keywords:

Solution Type  Technical Instruction Sure

Solution  1434045.1 :   Sun Storage 7000 Unified Storage System: Verifying the Fabric health to troubleshoot Fibre-Channel connectivity  


Related Items
  • Sun ZFS Storage 7420
  •  
  • Oracle ZFS Storage ZS3-2
  •  
  • Sun Storage 7110 Unified Storage System
  •  
  • Sun Storage 7210 Unified Storage System
  •  
  • Oracle ZFS Storage ZS4-4
  •  
  • Sun Storage 7410 Unified Storage System
  •  
  • Oracle ZFS Storage ZS3-4
  •  
  • Sun Storage 7310 Unified Storage System
  •  
  • Sun ZFS Storage 7120
  •  
  • Oracle ZFS Storage Appliance Racked System ZS4-4
  •  
  • Sun ZFS Storage 7320
  •  
  • Oracle ZFS Storage ZS3-BA
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>ZFS Storage>SN-DK: 7xxx NAS
  •  
  • _Old GCS Categories>Sun Microsystems>Storage - Disk>Unified Storage
  •  




In this Document
Goal
Solution
References


Applies to:

Sun Storage 7410 Unified Storage System - Version All Versions and later
Sun ZFS Storage 7320 - Version All Versions and later
Sun ZFS Storage 7420 - Version All Versions and later
Sun Storage 7310 Unified Storage System - Version All Versions and later
Sun ZFS Storage 7120 - Version All Versions and later
7000 Appliance OS (Fishworks)

Goal

Verifying the Fabric health for Fibre-Channel connectivity of the Unified Storage

Solution

This document will be useful for troubleshooting when transport errors / timeouts / target connectivity issues are seen on the host when it is connected over a fabric to the ZFSSA Unified Storage.

 

Verify SAN configuration and Zoning Setup

To ensure HBA's will not see each other, a minimum of one zone per initiator per fabric is needed.

Different methodologies of zoning exists, like WWN based zoning and San switch port based zoning.

Check for errors logged by the switches. This might require extra logging enabled on switches. This may be useful if link errors are seen.



Refer to the following documentation to troubleshoot fabric connectivity issues.

Document: Sun StorageTek[TM] Brocade SAN Switches: Troubleshooting hardware errors external to switch ( Doc ID 1020241.1 )
Document: Check zoning configuration to ensure initiator and target pair are properly zoned together. Refer to Technical Instruction: ( Doc ID 1020237.1 )
Document: SAN: Troubleshooting Solaris[TM] 10 (not for Solaris[TM] 8 & 9) Fibre Channel (FC) HBA list in "NOT CONNECTED" status. ( Doc ID 1303745.1 )
Document: SAN: How To Collect and Send Explorer Data to Oracle SAN Support  ( Doc ID 1273941.1 )
Document: Checking Interconnecting Elements (IEs) in a SAN/Fibre Channel (FC) path  ( Doc ID 1400156.1 )
Document: Brocade - What logs are required to troubleshoot a Brocade switch?  ( Doc ID 1003754.1 )
Document: McData - What logs are required to troubleshoot a McData switch?  ( Doc ID 1015572.1 )
Document: Cisco MDS switch - What logs are required to troubleshoot a Cisco MDS switch?  ( Doc ID 1016141.1 )
Document: Troubleshooting Fibre Channel HBA Performance  ( Doc ID 1283727.1 )

 

 