Applies to:Oracle ZFS Storage ZS4-4 - Version All Versions and laterOracle ZFS Storage Appliance Racked System ZS4-4 - Version All Versions and later Sun ZFS Storage 7120 - Version All Versions and later Oracle ZFS Storage ZS3-2 - Version All Versions and later Oracle ZFS Storage ZS3-4 - Version All Versions and later 7000 Appliance OS (Fishworks) GoalSteps required to confirm Fibre-Channel host connectivity with Oracle/Sun provided Host Bus Adapters (HBAs) installed in the appliance.
Solution1. Verify that the HBAs are seen / available to the host, even before the operating system loads.At the ok prompt: ok> reset-all
ok> probe-scsi-all
2. Confirm that the HBA is visible to the OS and the devices can be seen from the HBA.The following example outputs assume that there are 4 LUNs configured over 2 device paths, on the 7xxx cluster , 2 owned by each node (or head) a) Use the "luxadm -e port" command to verify HBA has established communication with a node. Example:
/devices/pci@0,0/pci10de,5d@e/pci1077,143@0/fp@0,0:devctl CONNECTED /devices/pci@0,0/pci10de,5d@e/pci1077,143@0,1/fp@0,0:devctl CONNECTED
Example:
#luxadm -e dump_map /devices/pci@0,0/pci10de,5d@e/pci1077,143@0/fp@0,0 Pos Port_ID Hard_Addr Port WWN Node WWN Type 0 b1300 0 2101001b323baa4c 2001001b323baa4c 0x0 (Disk device) 1 b1200 0 21000024ff2e4ec7 20000024ff2e4ec7 0x0 (Disk device) 2 b0300 0 21000024ff2a967c 20000024ff2a967c 0x1f (Unknown Type,Host Bus Adapter) # luxadm -e dump_map /devices/pci@0,0/pci10de,5d@e/pci1077,143@0,1/fp@0,0:devctl Pos Port_ID Hard_Addr Port WWN Node WWN Type 0 10a00 0 21000024ff2e4ec6 20000024ff2e4ec6 0x0 (Disk device) 1 10b00 0 2100001b321baa4c 2000001b321baa4c 0x0 (Disk device) 2 10d00 0 21000024ff2a967d 20000024ff2a967d 0x1f (Unknown Type,Host Bus Adapter)
Example:
Luxadm display output for lun owned by node A. The same is seen for the other lun owned by node A # luxadm display /dev/rdsk/c4t600144F0F8D6944400004E6090280004d0s2 DEVICE PROPERTIES for disk: /dev/rdsk/c4t600144F0F8D6944400004E6090280004d0s2 Vendor: SUN Product ID: ZFS Storage 7320 Revision: 1.0 Serial Num: Unformatted capacity: 3072.000 MBytes Read Cache: Enabled Minimum prefetch: 0x0 Maximum prefetch: 0x0 Device Type: Disk device Path(s): /dev/rdsk/c4t600144F0F8D6944400004E6090280004d0s2 /devices/scsi_vhci/disk@g600144f0f8d6944400004e6090280004:c,raw Controller /dev/cfg/c2 Device Address 21000024ff2e4ec7,1 Host controller port WWN 21000024ff2a967c Class secondary State STANDBY Controller /dev/cfg/c2 Device Address 2101001b323baa4c,1 Host controller port WWN 21000024ff2a967c Class primary State ONLINE Controller /dev/cfg/c3 Device Address 21000024ff2e4ec6,1 Host controller port WWN 21000024ff2a967d Class secondary State STANDBY Controller /dev/cfg/c3 Device Address 2100001b321baa4c,1 Host controller port WWN 21000024ff2a967d Class primary State ONLINE
The 2 active ones are to the 7xxx node which is serving the LUNs and the 2 standby ones are the paths to the other 7xxx node. If not configured, use cfgadm -c configure <Ap-ID> Example:
# cfgadm -al c5 fc-fabric connected configured unknown c5::21000024ff2e4ec6 disk connected configured unknown c5::2100001b321baa4c disk connected configured unknown c6 fc-fabric connected configured unknown c6::2101001b323baa4c disk connected configured unknown c6::21000024ff2e4ec7 disk connected configured unknown
cfgadm -c unconfigure -o unusable_FCP_dev cX::WWN
Verify by referring to the Document 1434004.1 Sun Storage 7000 Unified Storage System: Verifying that the Unified Storage has been configured correctly for Fibre-Channel connectivity #devfsadm -Cv -c disk
#luxadm -e forcelip /devices/pci@0,0/pci10de,5d@e/pci1077,143@0,1/fp@0,0:devctl
If errors are present, then verify the Fabric health by referring to Document 1434045.1 Sun Storage 7000 Unified Storage System: Verifying the Fabric health for Fibre-Channel connectivity Contact Oracle Support citing the exact problem. The host sees 4 FC luns
#format Searching for disks...done AVAILABLE DISK SELECTIONS: 0. c16t500000E010CC3B30d0 <SUN146G cyl 14087 alt 2 hd 24 sec 848> /scsi_vhci/ssd@g500000e010cc3b30 1. c4t600144F0F8D6944400004E60900A0003d0 <DEFAULT cyl 2557 alt 2 hd 128 sec 32> owned by node A of the 7xxx box /scsi_vhci/disk@g600144f0f8d6944400004e60900a0003 2. c4t600144F0F8D6944400004E6090280004d0 <DEFAULT cyl 1533 alt 2 hd 128 sec 32> owned by node A /scsi_vhci/disk@g600144f0f8d6944400004e6090280004 3. c4t600144F0991DB38600004E6091E60001d0 <DEFAULT cyl 2045 alt 2 hd 128 sec 32> owned by node B /scsi_vhci/disk@g600144f0991db38600004e6091e60001 4. c4t600144F0991DB38600004E6091FF0002d0 <DEFAULT cyl 2045 alt 2 hd 128 sec 32> owned by node B /scsi_vhci/disk@g600144f0991db38600004e6091ff0002 3. Correct errors reported by hosti). If the host experiences errors like:
*** Checked for relevance on 22-Aug-2013 *** *** Checked for relevance on 12-Jun-2017 ***
References<BUG:15663016> - SUNBT6977521 FCTL DRIVER PRODUCES "NS FAILURE PKT STATE" MESSAGES AFTER INSTALLI<BUG:15677847> - SUNBT6995579-SOLARIS_11 6956269 IS INCOMPLETE FIX AND FP_NHEAD2 SHOULD BE FP_NHE <BUG:15646201> - SUNBT6956269-SOLARIS_11 WARNING:FP(0)::FP_PLOGI_INTR ON NL NODES <NOTE:1434004.1> - Sun Storage 7000 Unified Storage System: Verifying that the Unified Storage has been configured correctly for Fibre-Channel connectivity <NOTE:1434045.1> - Sun Storage 7000 Unified Storage System: Verifying the Fabric health to troubleshoot Fibre-Channel connectivity Attachments This solution has no attachment |
||||||||||||||||||||||
|