![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Solution Type Technical Instruction Sure Solution 1432735.1 : M4000/M5000/M8000/M9000 Servers: Domain Configuration Information and Considerations
In this Document
Applies to:Sun SPARC Enterprise M8000 Server - Version Not Applicable and laterSun SPARC Enterprise M9000-32 Server - Version Not Applicable and later Sun SPARC Enterprise M9000-64 Server - Version Not Applicable and later Sun SPARC Enterprise M4000 Server - Version Not Applicable and later Sun SPARC Enterprise M5000 Server - Version Not Applicable and later Information in this document applies to any platform. GoalDevice Considerations and setup steps for Mx000 Servers. SolutionM4000 / M5000The below table shows which XSB is used with which device. When creating 2 domains on a M4000, the XSB 00-0 would be in one domain and XSB 00-1 will have to be used in the other domain to access an external boot device.
Creating a single domain on an M4000Setting up Domain 0 XSCF> setupfru -x 1 sb 0 XSCF> showfru sb 0 Device Location XSB Mode Memory Mirror Mode sb 00 Uni no XSCF> setdcl -d 0 -a 0=00-0 XSCF> addboard -c assign -d 0 00-0 XSB#00-0 will be assigned to DomainID 0. Continue?[y|n] :y XSCF> showdcl -v -d 0 DID LSB XSB Status No-Mem No-IO Float Cfg-policy 00 Powered Off FRU 00 00-0 False False False XSCF> showboards -a XSB DID(LSB) Assignment Pwr Conn Conf Test Fault ---- -------- ----------- ---- ---- ---- ------- -------- 00-0 00(00) Assigned y y n Passed Normal Creating two domain on an M4000Setting up Domain 0 XSCF> setupfru -x 4 sb 0 XSCF> showfru sb 0 Device Location XSB Mode Memory Mirror Mode sb 00 Quad no XSCF> setdcl -d 0 -a 0=00-0 XSCF> setdcl -d 0 -a 1=00-2 XSCF> addboard -c assign -d 0 00-0 00-2 XSB#00-0 will be assigned to DomainID 0. Continue?[y|n] :y XSB#00-2 will be assigned to DomainID 0. Continue?[y|n] :y XSCF> showdcl -v -d 0 DID LSB XSB Status No-Mem No-IO Float Cfg-policy 00 Powered Off FRU 00 00-0 False False False 01 00-2 False False False ...
XSCF> setdcl -d1 -a 0=00-1 XSCF> setdcl -d1 -a 1=00-3 XSCF> addboard -c assign -d 1 00-1 00-3 XSB#00-1 will be assigned to DomainID 1. Continue?[y|n] :y XSB#00-3 will be assigned to DomainID 1. Continue?[y|n] :y XSCF> showdcl -v -d 1 DID LSB XSB Status No-Mem No-IO Float Cfg-policy 01 Powered Off FRU 00 00-1 False False False 01 00-3 False False False ... XSCF> showboards -a XSB DID(LSB) Assignment Pwr Conn Conf Test Fault ---- -------- ----------- ---- ---- ---- ------- -------- 00-0 00(00) Assigned y y n Passed Normal 00-1 01(00) Assigned y y n Passed Normal 00-2 00(01) Assigned y y n Passed Normal 00-3 01(01) Assigned y y n Passed Normal M8000 / M9000
M8000/M9000 Unimode Graphics M8000/M9000 Quadmode Graphics M8000/M9000 IO RulesNOTE: In order to control the IOU hard disks the IOU has to be fitted with an IOU/A adaptor card in the following slots
IObox Link cards should only be installed in the odd numbered slots.
References
Attachments This solution has no attachment |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|