Solution Type  Technical Instruction Sure

Solution  1432735.1 :   M4000/M5000/M8000/M9000 Servers: Domain Configuration Information and Considerations  


Related Items
  • Sun SPARC Enterprise M9000-64 Server
  •  
  • Sun SPARC Enterprise M9000-32 Server
  •  
  • Sun SPARC Enterprise M8000 Server
  •  
  • Sun SPARC Enterprise M4000 Server
  •  
  • Sun SPARC Enterprise M5000 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: Mx000
  •  
  • _Old GCS Categories>Sun Microsystems>Servers>OPL Servers
  •  




In this Document
Goal
Solution
 M4000 / M5000
 Creating a single domain on an M4000
 Creating two domain on an M4000
 M8000 / M9000
  M8000/M9000 IO Rules
 References


Applies to:

Sun SPARC Enterprise M8000 Server - Version Not Applicable and later
Sun SPARC Enterprise M9000-32 Server - Version Not Applicable and later
Sun SPARC Enterprise M9000-64 Server - Version Not Applicable and later
Sun SPARC Enterprise M4000 Server - Version Not Applicable and later
Sun SPARC Enterprise M5000 Server - Version Not Applicable and later
Information in this document applies to any platform.

Goal

Device Considerations and setup steps for Mx000 Servers.

Solution

M4000 / M5000

The below table shows which XSB is used with which device.  When creating 2 domains on a M4000, the XSB 00-0 would be in one domain and XSB 00-1 will have to be used in the other domain to access an external boot device.

XSB CPU Memory Board I/O
PSB0  ( M4000 / M5000 )
00-0 CPUM#0-CHIP#0 MEMB#0 Disks 0 & 1, DVD/DAT, GbE, IOU#0-PCI#0, IOU#0-PCI#1, IOU#0-PCI#2
00-1 CPUM#0-CHIP#1 MEMB#1 IOU#0-PCI#3, IOU#0-PCI#4
00-2 CPUM#1-CHIP#0 MEMB#2 None
00-3 CPUM#1-CHIP#1 MEMB#3 None
PSB1 ( M5000 Only )
01-0 CPUM#2-CHIP#0 MEMB#4 Disks 2 & 3, GbE, IOU#1-PCI#0, IOU#1-PCI#1, IOU#1-PCI#2
01-1 CPUM#2-CHIP#1 MEMB#5 IOU#1-PCI#3, IOU#1-PCI#4
01-2 CPUM#3-CHIP#0 MEMB#6 None
01-3 CPUM#3-CHIP#1 MEMB#7 None

 

M4000 Graphics
 M4000 Uni Mode
M5000 Graphics
 M5000 Uni Mode

Creating a single domain on an M4000

Setting up Domain 0

XSCF> setupfru -x 1 sb 0
XSCF> showfru sb 0

Device  Location    XSB Mode        Memory Mirror Mode  
sb      00          Uni             no  
          
XSCF> setdcl -d 0 -a 0=00-0
XSCF> addboard -c assign -d 0 00-0

XSB#00-0 will be assigned to DomainID 0. Continue?[y|n] :y 

XSCF> showdcl -v -d 0
DID   LSB   XSB   Status   No-Mem   No-IO    Float    Cfg-policy
00                Powered Off                         FRU      
      00    00-0           False    False    False 


XSCF> showboards -a
XSB  DID(LSB) Assignment  Pwr  Conn Conf Test    Fault    
---- -------- ----------- ---- ---- ---- ------- -------- 
00-0 00(00)   Assigned    y    y    n    Passed  Normal 

Creating two domain on an M4000

Setting up Domain 0

XSCF> setupfru -x 4 sb 0
XSCF> showfru sb 0

Device  Location    XSB Mode        Memory Mirror Mode  
sb      00          Quad            no  
          
XSCF> setdcl -d 0 -a 0=00-0
XSCF> setdcl -d 0 -a 1=00-2
XSCF> addboard -c assign -d 0 00-0 00-2

XSB#00-0 will be assigned to DomainID 0. Continue?[y|n] :y
XSB#00-2 will be assigned to DomainID 0. Continue?[y|n] :y

XSCF> showdcl -v -d 0

DID   LSB   XSB   Status   No-Mem   No-IO    Float    Cfg-policy

00                Powered Off                         FRU      
      00    00-0           False    False    False             
      01    00-2           False    False    False             
 ...            


Setting up Domain 1

XSCF> setdcl -d1 -a 0=00-1             
XSCF> setdcl -d1 -a 1=00-3                             
XSCF> addboard -c assign -d 1 00-1 00-3

XSB#00-1 will be assigned to DomainID 1. Continue?[y|n] :y
XSB#00-3 will be assigned to DomainID 1. Continue?[y|n] :y

XSCF> showdcl -v -d 1

DID   LSB   XSB   Status   No-Mem   No-IO    Float    Cfg-policy

01                Powered Off                         FRU      
      00    00-1           False    False    False             
      01    00-3           False    False    False             
      ...  


XSCF> showboards -a

XSB  DID(LSB) Assignment  Pwr  Conn Conf Test    Fault    
---- -------- ----------- ---- ---- ---- ------- -------- 
00-0 00(00)   Assigned    y    y    n    Passed  Normal   
00-1 01(00)   Assigned    y    y    n    Passed  Normal   
00-2 00(01)   Assigned    y    y    n    Passed  Normal   
00-3 01(01)   Assigned    y    y    n    Passed  Normal   

M8000 / M9000

XSB CPU Memory I/O
PSBxx
xx-0 CPUM#0 MEM#00A,B IOU#xx-PCI#0
    MEM#01A,B IOU#xx-PCI#1
    MEM#02A,B  
    MEM#03A,B  
xx-1 CPUM#1 MEM#10A,B IOU#xx-PCI#2
    MEM#11A,B IOU#xx-PCI#3
    MEM#12A,B  
    MEM#13A,B  
xx-2 CPUM#2 MEM#20A,B IOU#xx-PCI#4
    MEM#21A,B IOU#xx-PCI#5
    MEM#22A,B  
    MEM#23A,B  
xx-3 CPUM#3 MEM#30A,B IOU#xx-PCI#6
    MEM#31A,B IOU#xx-PCI#7
    MEM#32A,B  
    MEM#33A,B  
 

M8000/M9000 Unimode Graphics

HighEnd Uni Mode

M8000/M9000 Quadmode Graphics

HighEnd Quad

 M8000/M9000 IO Rules

NOTE: In order to control the IOU hard disks the IOU has to be fitted with an IOU/A adaptor card in the following slots
  • Slot 0: control access to DVD/DAT, access to Base IO card's 2 gbe's, and control access to Disks 0 & 1
  • Slot 1:
  • Slot 2: control access to DVD/DAT, access to Base IO card's 2 gbe's
  • Slot 3:
  • Slot 4: control access to DVD/DAT, access to Base IO card's 2 gbe's, and control access to Disks 2 & 3
  • Slot 5:
  • Slot 6: control access to DVD/DAT, access to Base IO card's 2 gbe's
  • Slot 7:
IObox Link cards should only be installed in the odd numbered slots.

References

  • See also 1009927.1 Sun SPARC Enterprise Mx000 (OPL) Servers : Configuration Errors
  • See also 1019113.1 Sun Sparc Enterprise Mx000 (OPL) Servers Memory Configuration Rules

 


Attachments