Applies to:Sun SPARC Enterprise M8000 Server - Version Not Applicable and laterSun SPARC Enterprise M9000-32 Server - Version Not Applicable and later Sun SPARC Enterprise M9000-64 Server - Version Not Applicable and later Sun SPARC Enterprise M4000 Server - Version Not Applicable and later Sun SPARC Enterprise M5000 Server - Version Not Applicable and later Information in this document applies to any platform. GoalDevice Considerations and setup steps for Mx000 Servers. SolutionM4000 / M5000The below table shows which XSB is used with which device. When creating 2 domains on a M4000, the XSB 00-0 would be in one domain and XSB 00-1 will have to be used in the other domain to access an external boot device.
Creating a single domain on an M4000Setting up Domain 0 XSCF> setupfru -x 1 sb 0
XSCF> showfru sb 0
Device Location XSB Mode Memory Mirror Mode
sb 00 Uni no
XSCF> setdcl -d 0 -a 0=00-0
XSCF> addboard -c assign -d 0 00-0
XSB#00-0 will be assigned to DomainID 0. Continue?[y|n] :y
XSCF> showdcl -v -d 0
DID LSB XSB Status No-Mem No-IO Float Cfg-policy
00 Powered Off FRU
00 00-0 False False False
XSCF> showboards -a
XSB DID(LSB) Assignment Pwr Conn Conf Test Fault
---- -------- ----------- ---- ---- ---- ------- --------
00-0 00(00) Assigned y y n Passed Normal
Creating two domain on an M4000Setting up Domain 0 XSCF> setupfru -x 4 sb 0
XSCF> showfru sb 0
Device Location XSB Mode Memory Mirror Mode
sb 00 Quad no
XSCF> setdcl -d 0 -a 0=00-0
XSCF> setdcl -d 0 -a 1=00-2
XSCF> addboard -c assign -d 0 00-0 00-2
XSB#00-0 will be assigned to DomainID 0. Continue?[y|n] :y
XSB#00-2 will be assigned to DomainID 0. Continue?[y|n] :y
XSCF> showdcl -v -d 0
DID LSB XSB Status No-Mem No-IO Float Cfg-policy
00 Powered Off FRU
00 00-0 False False False
01 00-2 False False False
...
XSCF> setdcl -d1 -a 0=00-1
XSCF> setdcl -d1 -a 1=00-3
XSCF> addboard -c assign -d 1 00-1 00-3
XSB#00-1 will be assigned to DomainID 1. Continue?[y|n] :y
XSB#00-3 will be assigned to DomainID 1. Continue?[y|n] :y
XSCF> showdcl -v -d 1
DID LSB XSB Status No-Mem No-IO Float Cfg-policy
01 Powered Off FRU
00 00-1 False False False
01 00-3 False False False
...
XSCF> showboards -a
XSB DID(LSB) Assignment Pwr Conn Conf Test Fault
---- -------- ----------- ---- ---- ---- ------- --------
00-0 00(00) Assigned y y n Passed Normal
00-1 01(00) Assigned y y n Passed Normal
00-2 00(01) Assigned y y n Passed Normal
00-3 01(01) Assigned y y n Passed Normal
M8000 / M9000
M8000/M9000 Unimode Graphics M8000/M9000 Quadmode Graphics M8000/M9000 IO RulesNOTE: In order to control the IOU hard disks the IOU has to be fitted with an IOU/A adaptor card in the following slots
IObox Link cards should only be installed in the odd numbered slots.