How to remove and replace a SPARC T4-4 Server Rear I/O Module:ATR:1416400.1:0
Related Items |
- SPARC SuperCluster T4-4 Full Rack
- SPARC SuperCluster T4-4 Half Rack
- SPARC SuperCluster T4-4
- SPARC T4-4
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
In this Document
Applies to:
SPARC SuperCluster T4-4 Full Rack - Version All Versions and later
SPARC SuperCluster T4-4 - Version All Versions and later
SPARC T4-4 - Version All Versions and later
SPARC SuperCluster T4-4 Half Rack - Version All Versions and later
Information in this document applies to any platform.
Goal
How to remove and replace a SPARC T4-4 Server Rear I/O Module
***********************************************************************************
To report errors or request improvements on this procedure, please add a comment on Doc ID: 1416400.1
***********************************************************************************
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS ARE REQUIRED:
No special skills required, Customer Replaceable Unit (CRU) procedure
Time Estimate: 60 minutes
Task Complexity: 0
REMOVAL/REPLACEMENT INSTRUCTIONS
PROBLEM OVERVIEW: replace a faulty SPARC T4-4 Server Rear I/O Module
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
The customer should conduct an orderly software system shutdown. Then power down system and disconnect the power cords. A data backup is not a pre-requisite but is a wise precaution.
DAMAGE ALERT: Perform a visual inspection of the replacement part to make sure that there are no damaged components, connectors, bent pins, damaged packages during shipping, etc). If the part is damaged, don't install it into the system, order a new part. Handle with caution and package carefully the return part to avoid any damages during shipping.
WHAT ACTIONS ARE REQUIRED:
A) Remove the Rear I/O Module
The rear I/O module is a cold-service component that can be replaced by a customer.
1. Take the necessary ESD precautions.
2. Locate the failed rear I/O module. The System Service Required LED on the rear I/O module will light when a rear I/O module fault is detected
3. Power off the server.
4. Label the cables connected to the ports on the rear I/O module, then disconnect the cables from the ports.
You will reconnect the cables to the same ports on the replacement rear I/O module.
5. Press the green button on the rear I/O module ejection lever and lower the lever slightly.
6. Lower the lever completely to unseat the rear I/O module, and then pull the module away from the server to remove it.
B) Install the Rear I/O Module
1. Take the necessary ESD precautions.
2. With the lever in the lowered position, insert the rear I/O module into the slot at the rear of the server.
3. Raise the extraction lever up until it clicks into place, fully seating the rear I/O module into the server.
4. Connect the cables to the appropriate ports on the rear I/O module.
5. Power on the server.
6. Verify the rear I/O module functionality.
a. Verify that the System Service Required LED on the rear I/O module is not lit.
b. If no faults have been detected, then the rear I/O module has been replaced successfully. No further action is required.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Boot system and monitor boot sequence for errors. Test functionality of system:
1. Run the Solaris "fmadm faulty" and SP/ILOM "show faulty" command (if only ALOM is supported run "showfaults -v" command) to verify that the fault has been cleared.
2. Perform one of the following tasks based on your verification results:
* If the previous steps did not clear the fault, refer to doc 1004229.1 for information about the tools and methods you can use to diagnose and clear
component faults.
* If the previous steps indicate that no faults have been detected, the component has been replaced successfully. No further action is required
3. Restart software applications per applicable administration guides to resume system operation.
PARTS NOTE:
refer to: https://support.oracle.com/handbook_private/Systems/SPARC_T4_4/components.html#I/O
REFERENCE INFORMATION:
SPARC T4-4 Service Manual: http://docs.oracle.com/cd/E23411_01/index.html