Asset ID: |
1-71-1416353.1 |
Update Date: | 2017-11-28 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1416353.1
:
How to Remove and Replace a SPARC T4-4 Server Service Processor:ATR:1416353.1:0
Related Items |
- SPARC SuperCluster T4-4 Full Rack
- SPARC SuperCluster T4-4 Half Rack
- SPARC SuperCluster T4-4
- SPARC T4-4
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
In this Document
Applies to:
SPARC SuperCluster T4-4 Full Rack - Version All Versions and later
SPARC SuperCluster T4-4 - Version All Versions and later
SPARC T4-4 - Version All Versions and later
SPARC SuperCluster T4-4 Half Rack - Version All Versions and later
Information in this document applies to any platform.
Goal
How to Remove and Replace a SPARC T4-4 Server Service Processor
***********************************************************************************
To report errors or request improvements on this procedure, please add a comment on Doc ID: 1416353.1
***********************************************************************************
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS ARE REQUIRED:
No special skills required, Customer Replaceable Unit (CRU) procedure
Time Estimate: 240 minutes
Task Complexity: 0
REMOVAL/REPLACEMENT INSTRUCTIONS
PROBLEM OVERVIEW: replace a failed Service Processor
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
The customer should conduct an orderly software system shutdown. Then power down system and disconnect the power cords. A data backup is not a pre-requisite but is a wise precaution.
DAMAGE ALERT: Perform a visual inspection of the replacement part to make sure that there are no damaged components, connectors, bent pins, damaged packages during shipping, etc). If the part is damaged, don't install it into the system, order a new part. Handle with caution and package carefully the return part to avoid any damages during shipping.
NOTE: When possible, prior to replacement login to the ILOM/SP and check the reported version of System Firmware. If the server is running 8.9.5-8.9.5.a, update the System Firmware to 8.9.8 then proceed with replacement. This is to avoid running into "Error Reading Keyswitch Value" due to Bug 24489657.
NOTE: When replacing the service processor (SP), you must backup/restore the configuration settings maintained in the SP. Before replacing the SP, save the configuration using the Oracle ILOM backup utility. Refer to the Oracle Integrated Lights Out Manager (ILOM) 3.2.x Documentation for instructions on backing up and restoring the Oracle ILOM configuration: https://docs.oracle.com/cd/E37444_01/html/E37446/z400371a1482122.html
WHAT ACTIONS ARE REQUIRED:
A) Remove the Service Processor
The service processor is a cold-service component that can be replaced by a customer.
Note: Following SP/ILOM replacement if any device used by the LDOM configuration is disabled or faulted, the system will attempt to boot into a degraded configuration (if possible) or will revert to the factory-default profile. So, if the system is using Oracle VM (LDom) we recommend as a precaution to perform a backup of the LDom configuration (per doc 1019720.1) prior to SP replacement.
1. Back up the service processor configuration information before removing the service processor.
At the ILOM prompt, type:
-> cd /SP/config
-> dump -destination uri target
The acceptable values for uri are:
- tftp
- ftp
- sftp
- scp
- http
- https
- target is the remote location where you want to store the configuration information.
For example:
-> dump -destination tftp://129.99.99.99/pathname
2. Remove the main module from the server.
3. Take the necessary ESD precautions.
4. Locate the service processor on the main module.
5. Grasp the service processor by the two grasp points, and lift up to disengage the service processor from the connectors on the motherboard.
6. Lift the service processor up and away from the motherboard
B) Install the Service Processor
1. Lower the side of the service processor with the Align Tab sticker down on the service processor tab on the motherboard.
2. Lower the other side of the service processor down and press down on the service processor to seat it into the connectors on the motherboard.
3. Install the main module back into the server.
4. Connect a terminal or a terminal emulator (PC or workstation) to the serial management port.
If the replacement service processor detects that the service processor firmware is not compatible with the existing host firmware, further action will be suspended and the following message will be delivered over the serial management port
==========================================================================================
Unrecognized Chassis: This module is installed in an unknown or unsupported chassis. You must upgrade the firmware to a newer
version that supports this chassis.
==========================================================================================
If you see this message, go on to Step 5, otherwise go to Step 6.
5. Update the system firmware
a. Download the system firmware from My Oracle Support, the latest is SysFW 8.9.8, <SunPatch:152477-04>
b. Configure the service processor as network port to enable the firmware image to be downloaded.
Refer to the Oracle ILOM documentation for network configuration instructions.
c. Download the system firmware.
Follow the firmware download instructions in the Oracle ILOM documentation and the specific firmware patch.
Note - You can load any supported system firmware version, including the firmware revision that had been installed prior to the replacement of the service processor.
NOTE: In some cases when updating the SysFW via CLI (and during CLI execution), it may fail with the following error:
-> load -source tftp://xxx.xxx.xxx.xxx/Sun_System_Firmware-x_x_x_x-SPARC_Tx-x.pkg
Error reading keyswitch value
If that happens, refer to doc 1517032.1 for the workaround steps (confirmed by FSEs) and the fix.
6. Restore the service processor configuration information that you backed up earlier.
At the ILOM prompt, type:
-> cd /SP/config
-> load -source uri target
The acceptable values for uri are:
- tftp
- ftp
- sftp
- scp
- http
- https
- target is the remote location where you stored the configuration information.
For example:
-> load -source tftp://129.99.99.99/pathname
7. Set ILOM date/time (-> set /SP/clock datetime=MMDDhhmmYYYY.ss)
8. Verify the service processor.
NOTE: In case the FW upgrade via ILOM BUI fails, please use the CLI method (see example in doc 2019500.1). You may need a source of TFTP in order to upgrade firmware via CLI commands, for details refer to: Solaris[TM] Operating System: How to set-up a TFTP server. (Doc ID 1004474.1). See also doc 2076315.1 in References.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Boot system and monitor boot sequence for errors. Test functionality of system:
1. Run the Solaris "fmadm faulty" and SP/ILOM "show faulty" command (if only ALOM is supported run "showfaults -v" command) to verify that the fault has been cleared.
2. Perform one of the following tasks based on your verification results:
* If the previous steps did not clear the fault, refer to doc 1004229.1 for information about the tools and methods you can use to diagnose and clear
component faults.
* If the previous steps indicate that no faults have been detected, the component has been replaced successfully. No further action is required
3. Restart software applications per applicable administration guides to resume system operation.
PARTS NOTE:
refer to: https://support.oracle.com/handbook_private/Systems/SPARC_T4_4/components.html#SystemServiceProcessor
REFERENCE INFORMATION:
SPARC T4-4 Service Manual: http://docs.oracle.com/cd/E23411_01/index.html
See also: Oracle Integrated Lights Out Manager (ILOM) 3.0 Documentation Collection: http://docs.oracle.com/cd/E19860-01/index.html
References
<NOTE:1004474.1> - Solaris[TM] Operating System: How to set-up a TFTP server.
<NOTE:2076315.1> - Where to Find and How to use TFTP and ILOM CLI To Upgrade Firmware on T3, T4, T5, and T7 Systems when BUI Fails
<NOTE:2019500.1> - System firmware upgrade via ILOM BUI fails with "Package Structure Is Corrupted" on T4 systems
Attachments
This solution has no attachment