Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1415497.1
Update Date:2016-04-25
Keywords:

Solution Type  Technical Instruction Sure

Solution  1415497.1 :   How to Replace a SPARC T4-2 or Netra T4-2 Battery:ATR:1415497.1:0  


Related Items
  • SPARC T4-2
  •  
  • Netra SPARC T4-2 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
Goal
Solution


Applies to:

SPARC T4-2 - Version All Versions and later
Netra SPARC T4-2 Server - Version All Versions and later
Information in this document applies to any platform.

Goal

Replace T4-2 battery.

***********************************************************************************
To report errors or request improvements on this procedure, please Add a comment on Doc ID: 1415497.1
***********************************************************************************

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS ARE REQUIRED
No special skills required, Customer Replaceable Unit (CRU) procedure

Time Estimate: 60 minutes

Task Complexity: 0

REMOVAL/REPLACEMENT INSTRUCTIONS

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
The customer should conduct an orderly software system shutdown. Then power down system and disconnect the power cords. A data backup is not a pre-requisite but is a wise precaution.

DAMAGE ALERT: Perform a visual inspection of the replacement part to make sure that there are no damaged components, connectors, bent pins, damaged packages during shipping, etc. If the part is damaged, don't install it into the system, order a new part. Handle with caution and package carefully the return part to avoid any damages during shipping.

 
WHAT ACTIONS ARE REQUIRED:

A) Replace the System Battery

1. Prepare for servicing:
a. Attach an antistatic wrist strap.
b. Power off the server and unplug power cords from the power supplies.
c. Extend the server to maintenance position.
d. Remove the top cover.

2. Remove the battery from the battery holder by pulling back on the metal tab holding it in place and sliding the battery up and out of the battery holder.  (PCIe 0 must be removed first on the Netra)

3. Unpack the replacement battery.

4. Press the new battery into the battery holder with the positive side (+) facing away from the metal tab that holds it in place.  (Replace PCIe 0 if a Netra)

5. Return the server to operation:
a. Return the server to the normal rack position.
b. Reinstall the power cords to the power supplies and power on the server.

6. If the service processor is configured to synchronize with a network time server using the Network Time Protocol (NTP), the ILOM clock will be reset as soon as the server is powered on and connected to the network. Otherwise, proceed to the next step.

7. If the service processor is not configured to use NTP, you must reset the ILOM clock using the ILOM CLI or the web interface. For instructions, see the Oracle Integrated Lights Out Manager (ILOM) 3.0 Documentation Collection.


Using the Ilom CLI to set the date and time:

The following example sets the date to June 17, 2010, the time to 16:19:56, and the timezone to GMT.

-> set /SP/clock datetime=061716192010

-> show /SP/clock

/SP/clock
Targets:

Properties:
datetime = Wed JUN 17 16:19:56 2010
timezone = GMT (GMT)
usentpserver = disabled
Commands:
cd
set
show


B) Verify the System Battery

1. Run show /SYS/MB/BAT to check the status of the system battery. In the output, the /SYS/MB/BAT status should be “OK”, as in the following example.

-> show /SYS/MB/BAT
/SYS/MB/BAT

Targets:

Properties:
type = Battery
ipmi_name = MB/BAT
fault_state = OK
clear_fault_action = (none)

Commands:
cd
set
show

->

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Verify functionality, no service LEDs or messages.

PARTS NOTE:
refer to: https://support.oracle.com/handbook_private/Systems/SPARC_T4_2/components.html#Batteries

  or:  https://support.oracle.com/handbook_private/Systems/Netra_T4_2/components.html#Batteries

REFERENCE INFORMATION:

SPARC T4-2 Service Manual: http://docs.oracle.com/cd/E23075_01/index.html  or http://docs.oracle.com/cd/E21893_01/index.html

See also Oracle Integrated Lights Out Manager (ILOM) 3.0 Documentation Collection:
http://docs.oracle.com/cd/E19860-01/index.html


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback