Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1415407.1
Update Date:2016-04-25
Keywords:

Solution Type  Technical Instruction Sure

Solution  1415407.1 :   How to Replace a SPARC T4-2 or Netra T4-2 DVD Drive:ATR:1415407.1:0  


Related Items
  • SPARC T4-2
  •  
  • Netra SPARC T4-2 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




Applies to:

SPARC T4-2 - Version All Versions and later
Netra SPARC T4-2 Server - Version All Versions and later
Information in this document applies to any platform.

Goal

How to Replace a T4-2 DVD Drive

********************************************************************************
To report errors or request improvements on this procedure, please put a comment on Doc ID: 1415407.1
********************************************************************************

Solution

CAP PROBLEM OVERVIEW:  T4-2 Server, DVD Drive replacing.

DISPATCH INSTRUCTIONS

WHAT SKILLS ARE REQUIRED?: No special skills required, Customer Replaceable Unit (CRU) procedure

Time Estimate: 60 minutes

Task Complexity: 0

REMOVAL/REPLACEMENT INSTRUCTIONS

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

The customer should conduct an orderly software system shutdown. Then power down system and disconnect the power cords. A data backup is not a pre-requisite but is a wise precaution.

DAMAGE ALERT: Perform a visual inspection of the replacement part to make sure that there are no damaged components, connectors, bent pins, damaged packages during shipping, etc. If the part is damaged, don't install it into the system, order a new part. Handle with caution and package carefully the return part to avoid any damages during shipping.


WHAT ACTIONS ARE REQUIRED:

Prepare for servicing:

a. Attach an antistatic wrist strap.
b. Remove any media from the drive.
c. Power off the server and unplug power cords from the power supplies.

Removing DVD drive

1. (Netra only) Remove the 2 hard drives below the DVD.
2. Push down on the latch on the top left corner of the DVD drive or filler panel.  (On Netra pull the green tab under the right of the DVD)
3. Slide the DVD drive or filler panel out of the server.

Caution: Whenever you remove the DVD drive or filler panel, you should replace it with another DVD drive or a filler panel; otherwise the server might overheat due to improper airflow.

Installing DVD drive

1. Unpack the DVD drive or filler panel. If it is a DVD drive, attach an antistatic wrist wrap and place the drive on an antistatic mat.
2. Slide the DVD drive or filler panel into the front of the chassis until it seats.
3. (Netra only) Insert the 2 hard drives below the DVD.
4. Return the server to operation:
a. Return the server to the normal rack position.
b. Reinstall the power cords to the power supplies and power on the server.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

Verify functionality, no service LEDs or messages.

PARTS NOTE:
refer to: https://support.oracle.com/handbook_private/Systems/SPARC_T4_2/components.html#RemovableMedia

  or: https://support.oracle.com/handbook_private/Systems/Netra_T4_2/components.html#RemovableMedia

REFERENCE INFORMATION:
SPARC T4-2 Service Manual: http://docs.oracle.com/cd/E23075_01/index.html or http://docs.oracle.com/cd/E21893_01/index.html


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback