Goal
Service SPARC T4-1 Internal RAID controller cable
********************************************************************************
To report errors or request improvements on this procedure,
please go to http://support.us.oracle.com and put a comment on Doc ID: 1413945.1
********************************************************************************
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
SPARC T4-1 product training
Time Estimate: 30 minutes
TASK COMPLEXITY: 1
FIELD ENGINEER INSTRUCTIONS
PROBLEM OVERVIEW: Service Internal RAID controller cable
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
DAMAGE ALERT: Perform a visual inspection of the replacement part to make sure that there are no damaged components, connectors, bent pins, damaged packages during shipping, etc. If the part is damaged, don't install it into the system, order a new part. Handle with caution and package carefully the return part to avoid any damages during shipping.
Note - This is a cold service procedure that can be performed by customers.
Caution - This procedure involves handling circuit boards that are extremely sensitive to static electricity. Ensure that you follow ESD preventative practices to avoid damaging the circuit boards.
Caution - Components inside the chassis might be hot. Use caution when servicing components inside the chassis.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
* Follow standard ESD procedures to avoid Electrostatic Discharge
1. Power off the server
2. Disconnect all power cables
3. Disconnect any data cables connected to any PCIe/XAUI card if needed
4. Remove the Top Cover
1. Unlatch the fan module door by pulling the release tabs back to release the door
2. Press the top cover release button and slide the top cover to the rear about a 0.5 inch
3. Lift up and remove the cover
5. Replace cables routing them as they were before
1. Connect the SFF-8087 x4 Mini-SAS connector on one end of the SAS cable to the internal port JT6 or JT7)
2. Connect the other end of the SFF-8087 x4 Mini-SAS cable to the connector on the SAS drive or SATA drive
6. After replacement reverse the order of fixing as mentioned in above points
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Boot system and monitor boot sequence for errors. Test functionality of system, check all disks access. Restart software applications per applicable administration guides to resume system operation.
PARTS NOTE: https://support.oracle.com/handbook_partner/Systems/SPARC_T4_1/components.html#Cables
REFERENCE INFORMATION: http://docs.oracle.com/cd/E22985_01/index.html