Technical Instruction Sure
Solution
1407494.1
:
How To Replace A PSU In The Oracle ZFS Storage ZS Or Sun Storage 7000 Series [VCAP]
Related Items |
- Sun ZFS Storage 7320
- Oracle ZFS Storage ZS3-BA
- Sun Storage 7210 Unified Storage System
- Oracle SuperCluster M6-32 Hardware
- Oracle SuperCluster T5-8 Hardware
- Oracle ZFS Storage ZS3-2
- Sun Storage 7410 Unified Storage System
- Oracle ZFS Storage ZS3-4
- SPARC SuperCluster T4-4 Half Rack
- Sun ZFS Storage 7420
- Oracle ZFS Storage ZS4-4
- SPARC SuperCluster T4-4
- Sun Storage 7310 Unified Storage System
- SPARC SuperCluster T4-4 Full Rack
- Exalogic Elastic Cloud X4-2 Half Rack
- PDIT Single Rack ZFS Storage ZS4-4
- Sun ZFS Storage 7120
- Sun ZFS Backup Appliance
- Sun Storage 7110 Unified Storage System
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: DISK-CAP VCAP
- Microlearning>Video>ML-VID-VCAP
|
In this Document
Applies to:
Oracle SuperCluster T5-8 Hardware - Version All Versions to All Versions [Release All Releases]
SPARC SuperCluster T4-4 Full Rack - Version All Versions to All Versions [Release All Releases]
SPARC SuperCluster T4-4 Half Rack - Version All Versions to All Versions [Release All Releases]
Oracle ZFS Storage ZS3-BA - Version All Versions to All Versions [Release All Releases]
Oracle ZFS Storage ZS4-4 - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Goal
How To Replace A PSU In The Oracle ZFS Storage ZS3 Or Sun Storage 7000 Series
Solution
DISPATCH INSTRUCTIONS
- WHAT SKILLS ARE REQUIRED?: No special skills required, Customer Replaceable Unit (CRU) procedure
- TIME ESTIMATE: 30 minutes
- TASK COMPLEXITY: 0
- PROBLEM OVERVIEW
What: The power supply in the NAS needs replacement
Where: Chassis S/N: , PSU Slot No. of the device to be inserted here by SR owner
Why : The PSU has failed in the NAS and should have an amber light on it.
REPLACEMENT INSTRUCTIONS
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?
No downtime needs to be scheduled, and the system can be in full production as they are redundant.
WHAT ACTIONS ARE REQUIRED?:
1. Locate the PSU by amber LED.
The following LEDs are lit when a power supply fault is detected:
* Front and rear Service Required LEDs
* Rear PS Failure LED on the bezel of the server
* Failure LED on the faulty power supply
2. Take ESD Precautions.
3. Check the PSU part numbers for the appropriate system in the System Handbook and re-confirm.
4. Removing the Power Supply as follows or use the "online" Help Guide.
* If present, remove cable management arm, or swivel open cable management arm to view power supplies.
* Disconnect the AC power cord that is connected to power supply you want to replace.
* Remove installed power supply unit by pulling its handle downward until it disengages unit from
connector on PDB. Pull out power supply.
5. Installing the Power Supply as follows or use the "online" Help Guide.
* Align power supply with empty bay in chassis.
*With power supply handle in down position, push power supply into power supply bay.
* Connect AC power cord to new power supply. Use the power cord retaining clips.
*If present, swivel cable management arm back into closed position.
6. Verify the replacement by checking for Green LED
WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE?:
Confirm there are no faults reported in the appliance BUI. Mark "Repaired" any prior faults related to the PSU
PARTS NOTE:
Please refer to the FE handbook for all PSU part number for conformation of correct type.
EXTERNAL REFERENCES:
Oracle Unified Storage Systems Documentation :
http://www.oracle.com/technetwork/documentation/oracle-unified-ss-193371.html
Sun ZFS Storage Appliances Troubleshooting Resource Center (Doc ID 1416406.1)
References
<NOTE:1416406.1> - Sun ZFS Storage Appliances Troubleshooting Resource Center
<NOTE:1333423.1> - Sun Storage 7000 Unified Storage System: "Failed Power Supply 'PSU 0' is not operating properly due to some external condition"
<NOTE:1324428.1> - Sun Storage 7000 Unified Storage System: Power Supply Troubleshooting
Attachments