Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1404465.1
Update Date:2017-05-12
Keywords:

Solution Type  Technical Instruction Sure

Solution  1404465.1 :   What is the Maximum Number of Drives Supported by the Sun Storage 6000 and 2500 Arrays ?  


Related Items
  • Sun Storage 6180 Array
  •  
  • Sun Storage 6580 Array
  •  
  • Sun Storage Flexline 280 Array
  •  
  • Sun Storage 2540 Array
  •  
  • Sun Storage 2510 Array
  •  
  • Sun Storage 6780 Array
  •  
  • Sun Storage 2540-M2 Array
  •  
  • Sun Storage 6140 Array
  •  
  • Sun Storage Flexline 210 Array
  •  
  • Sun Storage 2530-M2 Array
  •  
  • Sun Storage Flexline 380 Array
  •  
  • Sun Storage 2530 Array
  •  
  • Sun Storage 6540 Array
  •  
  • Sun Storage 6130 Array
  •  
  • Sun Storage Flexline 240 Array
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>Arrays>SN-DK: 6130
  •  
  • _Old GCS Categories>Sun Microsystems>Storage - Disk>Modular Disk - 6xxx Arrays
  •  




In this Document
Goal
Solution


Created from <SR 3-4999136090>

Applies to:

Sun Storage 2540 Array - Version Not Applicable and later
Sun Storage 6180 Array - Version Not Applicable and later
Sun Storage 2510 Array - Version Not Applicable and later
Sun Storage 2530-M2 Array - Version Not Applicable and later
Sun Storage 6580 Array - Version Not Applicable and later
Information in this document applies to any platform.

Goal

 

To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - Disk Storage 2000, 3000, 6000 RAID Arrays & JBODs Community.



The intent of this document is to list the maximum number of drives allowable on the following arrays:

  • StorageTek 2500 series.
  • Sun Storage 2500-M2 series.
  • StorageTek 6130.
  • StorageTek 6140.
  • Sun Storage 6180.
  • StorageTek 6540.
  • Sun Storage 6580.
  • Sun Storage 6780.
  • Sun Storage Flexline 210.
  • Sun Storage Flexline 240.
  • Sun Storage Flexline 280.
  • Sun Storage Flexline 380.

Solution

Below are the maximum number of drives supported for each model of storage array:

ModelMaximum Number of DrivesFirmware RequiredNote
6780 448 7.50.xx.xx and higher  
6780 256 7.36.xx.xx and lower  
6580 256    
6180 64   4 host ports per controller tray
6180 112   8 host ports per controller tray
6540 224   112 per channel pair
FLX380 224   112 per channel pair
6140 112    
6130 112    
FLX280 224   112 per channel pair
FLX240 (drive limited) 14   The controller module will not have any external drive module ports.
FLX240 (non-drive limited) 112    
FLX210 112    
2540-M2 (4GB Cache) 192 7.84.xx.xx and higher  
2540-M2/2530-M2 (2GB Cache) 96 7.80.xx.xx and higher  
2540-M2/2530-M2 (2GB Cache) 48 7.77.xx.xx and lower  
2540/2530/2510 48 6.70.54.10 and higher  
2540/2530/2510 36 6.70.42.10 and lower  