Asset ID: |
1-71-1404465.1 |
Update Date: | 2017-05-12 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1404465.1
:
What is the Maximum Number of Drives Supported by the Sun Storage 6000 and 2500 Arrays ?
Related Items |
- Sun Storage 6180 Array
- Sun Storage 6580 Array
- Sun Storage Flexline 280 Array
- Sun Storage 2540 Array
- Sun Storage 2510 Array
- Sun Storage 6780 Array
- Sun Storage 2540-M2 Array
- Sun Storage 6140 Array
- Sun Storage Flexline 210 Array
- Sun Storage 2530-M2 Array
- Sun Storage Flexline 380 Array
- Sun Storage 2530 Array
- Sun Storage 6540 Array
- Sun Storage 6130 Array
- Sun Storage Flexline 240 Array
|
Related Categories |
- PLA-Support>Sun Systems>DISK>Arrays>SN-DK: 6130
- _Old GCS Categories>Sun Microsystems>Storage - Disk>Modular Disk - 6xxx Arrays
|
In this Document
Created from <SR 3-4999136090>
Applies to:
Sun Storage 2540 Array - Version Not Applicable and later
Sun Storage 6180 Array - Version Not Applicable and later
Sun Storage 2510 Array - Version Not Applicable and later
Sun Storage 2530-M2 Array - Version Not Applicable and later
Sun Storage 6580 Array - Version Not Applicable and later
Information in this document applies to any platform.
Goal
The intent of this document is to list the maximum number of drives allowable on the following arrays:
- StorageTek 2500 series.
- Sun Storage 2500-M2 series.
- StorageTek 6130.
- StorageTek 6140.
- Sun Storage 6180.
- StorageTek 6540.
- Sun Storage 6580.
- Sun Storage 6780.
- Sun Storage Flexline 210.
- Sun Storage Flexline 240.
- Sun Storage Flexline 280.
- Sun Storage Flexline 380.
Solution
Below are the maximum number of drives supported for each model of storage array:
Model | Maximum Number of Drives | Firmware Required | Note |
6780 |
448 |
7.50.xx.xx and higher |
|
6780 |
256 |
7.36.xx.xx and lower |
|
6580 |
256 |
|
|
6180 |
64 |
|
4 host ports per controller tray |
6180 |
112 |
|
8 host ports per controller tray |
6540 |
224 |
|
112 per channel pair |
FLX380 |
224 |
|
112 per channel pair |
6140 |
112 |
|
|
6130 |
112 |
|
|
FLX280 |
224 |
|
112 per channel pair |
FLX240 (drive limited) |
14 |
|
The controller module will not have any external drive module ports. |
FLX240 (non-drive limited) |
112 |
|
|
FLX210 |
112 |
|
|
2540-M2 (4GB Cache) |
192 |
7.84.xx.xx and higher |
|
2540-M2/2530-M2 (2GB Cache) |
96 |
7.80.xx.xx and higher |
|
2540-M2/2530-M2 (2GB Cache) |
48 |
7.77.xx.xx and lower |
|
2540/2530/2510 |
48 |
6.70.54.10 and higher |
|
2540/2530/2510 |
36 |
6.70.42.10 and lower |
|
Attachments
This solution has no attachment