![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Technical Instruction Sure Solution 1404012.1 : Flash Accelerator F20 PCIe Card Firmware Upgrade Procedure
Created from <SR 3-5122511111> Applies to:Sun Fire X4270 M2 Server - Version Not Applicable and laterSun Fire X4170 M2 Server - Version Not Applicable and later Information in this document applies to any platform. GoalThis document is intended to guide customers through upgrading the firmware on the F20 flash card, and its flash disks. SolutionThe easiest way to upgrade the firmware on this card is to use the fwupdate utility provided in the Oracle Hardware Management Pack. The Oracle Hardware Management Pack can be downloaded directly from My Oracle Support website and is available for various Operating Systems, including Windows, RedHat, OEL, and Solaris. To view the supported matrices for the Oracle Hardware Management Pack, refer to this website: Check the Version of the Firmware:
# fwupdate list disk
============================================================================== CONTROLLER ============================================================================== ID Manufacturer Model Product Name FW Version BIOS Version XML Support ------------------------------------------------------------------------------ c6 LSI Logic 0x0058 SAS1068E 01.27.03.00-IT 6.26.00.00 N/A DISKS ============================================================================== ID Manufacturer Model Chassis Slot Type Media Size (GB) FW Version XML Support ------------------------------------------------------------------------------ c6d0 MARVELL SD88SA02 - 0 sata SSD 24 DP0N N/A c6d1 MARVELL SD88SA02 - 1 sata SSD 24 DP0N N/A c6d2 MARVELL SD88SA02 - 2 sata SSD 24 DP0N N/A c6d3 MARVELL SD88SA02 - 3 sata SSD 24 DP0N N/A
Update the Firmware of the pci card:1. Copy the new firmware image onto the system. The new firmware can be downloaded directly from My Oracle Support. # fwupdate update sas-controller-firmware -n c6 -f /LSI_1068E_B3-F20-1.27.92.00.fw
The following components will be upgraded as shown: =========================================================================== ID Priority Action Status Old Firmware Ver. Proposed Ver. New Firmware Ver. System Reboot --------------------------------------------------------------------------- c6 1 Check FW Success 01.27.03.00-IT Not Provided N/A None Do you wish to process all of the above component upgrades? [y/n]? y Updating c0: Success Verifying all priority 1 updates No metadata provided, so version verification can not be completed Execution Summary =========================================================================== ID Priority Action Status Old Firmware Ver. Proposed Ver. New Firmware Ver. System Reboot --------------------------------------------------------------------------- c6 1 Validate Pending 01.27.03.00-IT Not Provided 01.27.92.00-IT None
# fwupdate list disk
=========================================================================== CONTROLLER =========================================================================== ID Manufacturer Model Product Name FW Version BIOS Version XML Support --------------------------------------------------------------------------- c6 LSI Logic 0x0058 SAS1068E 01.27.92.00-IT 6.26.00.00 N/A Update the Firmware of the flash modules:1. Copy the new firmware image onto the system. The new firmware can be downloaded directly from My Oracle Support. # fwupdate update disk -n c6d0 -x D21Y_metadata.xml The following message will appear on the screen: The following components will be upgraded as shown: ========================================================== ID Priority Action Status Old Firmware Ver. Proposed Ver. New Firmware Ver. System Reboot -------------------------------------------------------------------------------------------------------------------- c6d0 1 Check FW Success D20Y D21Y N/A System Power Do you wish to process all of the above component upgrades? [y/n]? y Updating c2d0: Success Verifying all priority 1 updates Execution Summary ========================================================== ID Priority Action Status Old Firmware Ver. Proposed Ver. New Firmware Ver. System Reboot -------------------------------------------------------------------------------------------------------------------- c6d0 1 Post Power Pending D20Y D21Y N/A System Power System Reboot required for some applied firmware Do you wish to automatically reboot now? [y/n]? y Repeat the above example for c6d1, c6d2 and c6d3.
# fwupdate list disk DISKS =============== ID Brand Model Chassis Slot Type Media Size (GB)Firmware Revision -------------------------------------------------------------------------------------------------------------------- c6d0 MARVELL SD88SA02 0 14 sata SSD 24 D21Y c6d1 MARVELL SD88SA02 0 14 sata SSD 24 D21Y c6d2 MARVELL SD88SA02 0 14 sata SSD 24 D21Y c6d3 MARVELL SD88SA02 0 14 sata SSD 24 D21Y