![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Technical Instruction Sure Solution 1393271.1 : How to Replace a Sun Fire X4800, Sun Server X2-8 (Sun Fire X4800 M2) HDD
In this Document
Applies to:Sun Server X2-8 - Version Not Applicable and laterSun Fire X4800 Server - Version Not Applicable and later Information in this document applies to any platform. GoalHow to Replace a Sun Fire X4800, Sun Server X2-8 (Sun Fire X4800 M2) HDD. Solution
DISPATCH INSTRUCTIONS WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED: TIME ESTIMATE: 60 minutes TASK COMPLEXITY: 0 FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS: PROBLEM OVERVIEW: A Sun Fire X4800, Sun Server X2-8 (Sun Fire X4800 M2) HDD needs replacement WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : The disk could be replaced with online =============================================================================
Caution - Airflow and temperature control related issues. Do not leave a hard drive slot unoccupied. Hard drive slots must contain either a drive or a HD filler. Caution - Possible component damage. The handle does not extend to a 90-degree angle. Do not extend the handle beyond its limitation. =============================================================================
-> show /SYS/DBP/HDD0
/SYS/DBP/HDD0 Properties: type = Hard Disk ipmi_name = DBP/HDD0 /SYS/DBP/HDD0/SERVICE Properties: type = Indicator ipmi_name = DBP/HDD0/SVC value = Off /SYS/DBP/HDD0/OK2RM Properties: type = Indicator ipmi_name = DBP/HDD0/OK2RM value = Off
-> show /SP/faultmgmt
-> show /SP/logs/event/list
For LSI SGX-SAS6-R-REM-Z(6Gbps SAS-2 RAID Expansion Module) controller.
Online check without shutdown: ./MegaCli -LdPdInfo -aALL
Adapter #0 Number of Virtual Disks: 9 Virtual Drive: 0 (Target Id: 0) Name : RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0 Size : 278.464 GB Sector Size : 512 Is VD emulated : No Mirror Data : 278.464 GB State : Optimal<<<<<<<<<<< Strip Size : 64 KB Number Of Drives : 2 Span Depth : 1 Default Cache Policy: WriteBack, ReadAheadNone, Cached, No Write Cache if Bad BBU Current Cache Policy: WriteBack, ReadAheadNone, Cached, No Write Cache if Bad BBU Default Access Policy: Read/Write Current Access Policy: Read/Write . . PD: 0 Information Enclosure Device ID: 22 Slot Number: 0 . . Firmware state: Online, Spun Up<<<<<<<<<<< Commissioned Spare : No Emergency Spare : No Device Firmware Level: A606 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5000cca05430f641 SAS Address(1): 0x0 Connected Port Number: 0(path0) Inquiry Data: HITACHI H109030SESUN300GA6061429CVXS5F . . Drive has flagged a S.M.A.R.T alert : No
If OS not installed MegaCli utilities, we can install MegaCli utilities from http://www.avagotech.com/support/oem/oracle/6gb/sg_x_sas6-r-rem-z. Otherwise, reboot server to check disk status. For LSI SGX-SAS6-EM-Z(8-Port 6Gbps SAS-2 RAID HBA Module) RAID controller.
Online check without shutdown: ./sas2ircu 0 display all
LSI Corporation SAS2 IR Configuration Utility. Version 11.00.00.03 (2011.10.14) Copyright (c) 2009-2011 LSI Corporation. All rights reserved. . . ------------------------------------------------------------------------ Physical device information ------------------------------------------------------------------------ Initiator at ID #0 Device is a Hard disk Enclosure # : 2 Slot # : 0 SAS Address : 5000cca-0-2270-f591 State : Ready (RDY)<<<<<<<<<<<< Size (in MB)/(in sectors) : 286102/585937499 Manufacturer : HITACHI Model Number : H109030SESUN300G Firmware Revision : A690 Serial No : 1333C03UTR GUID : 5000cca02270f590 Protocol : SAS Drive Type : SAS_HDD If OS not installed sas2ircu utilities, we can install sas2ircu utilities from http://www.avagotech.com/support/oem/oracle/6gb/sg_x_sas6-rem-z. 1. Power On system # format
Searching for disks...done AVAILABLE DISK SELECTIONS: 0. c0t0d0 <DEFAULT cyl 36348 alt 2 hd 255 sec 63> /pci@0,0/pci8086,3408@1/pci1000,9262@0/sd@0,0
# iostat -E
sd1 Soft Errors: 0 Hard Errors: 0 Transport Errors: 0 Vendor: LSI Product: MR9262-8i Revision: 2.90 Serial No: Size: 299.00GB <298999348736 bytes> Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0 Illegal Request: 2 Predictive Failure Analysis: 0
# cfgadm -alv
Ap_Id Receptacle Occupant Condition Information When Type Busy Phys_Id Slot3 empty unconfigured unknown Location: Slot3 Jan 1 1970 unknown n /devices/pci@79,0/pci8086,340a@3:Slot3 Slot5 connected configured ok Location: Slot5 Jan 1 1970 pci-pci/hp n /devices/pci@79,0/pci8086,340c@5:Slot5 c0 connected configured unknown unavailable scsi-bus n /devices/pci@0,0/pci8086,3408@1/pci1000,9262@0:scsi c0::dsk/c0t0d0 connected configured unknown LSI MR9262-8i
References<NOTE:1536918.1> - Replacing a drive on 8-Port 6Gbps SAS-2 RAID HBA / 6Gbps SAS-2 RAID Expansion Module (NIWOT) that has not been explicitly failed by the system<NOTE:1010946.1> - General Guidance for Diagnosis (Disk Failures/Errors) and Replacing Internal Server Disks and JBOD Disks within Solaris <NOTE:1011590.1> - How to check for Windows platform disk errors and online/offline status <NOTE:1013107.1> - How to Identify BIOS and Solaris[TM] Hardware RAID Status <NOTE:1002753.1> - How to Replace a Drive in Solaris[TM] ZFS <NOTE:1005530.1> - How To Check for Disk Errors and Online/Offline Status on Oracle Platforms Running Solaris x86 <NOTE:1002936.1> - How To Check for Linux Platform Disk Errors and Online/Offline Status Attachments This solution has no attachment |
||||||||||||||||
|