Asset ID: |
1-71-1392805.1 |
Update Date: | 2017-08-23 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1392805.1
:
CAM - How to Remove and Replace 2500-M2 RAID Controller [VCAP]
Related Items |
- Sun Storage 2530-M2 Array
- Sun Storage 2540-M2 Array
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: DISK-CAP VCAP
- Microlearning>Video>ML-VID-VCAP
- _KM>Content>Video
|
In this Document
Applies to:
Sun Storage 2540-M2 Array - Version All Versions to All Versions [Release All Releases]
Sun Storage 2530-M2 Array - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Goal
How to Remove and Replace a 2530-M2/2540-M2 Disk Array RAID Controller
Solution
DISPATCH INSTRUCTIONS
TIME ESTIMATE: 60 minutes
TASK COMPLEXITY: 0
WHAT SKILLS DOES THE ADMINISTRATOR OR ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
None. This is a Customer Replaceable Unit with no training requirement.
FIELD ENGINEER INSTRUCTIONS
PROBLEM OVERVIEW:
RAID Controller has been determined as failed.
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
Array power must be on. DO NOT replace the controller with the power off.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
NOTE: If ASR is enabled, it should be deactivated temporarily before servicing the equipment so that additional unnecessary Service Requests are not created.
DEACTIVATING ASR WITH CAM 6.10: ASR is automatically deactivated when you select "Reserve the tray for maintenance" in Service Advisor, and it is reactivated when you select "Release the tray from maintenance" in Service Advisor.
DEACTIVATING ASR WITH CAM 6.9 OR EARLIER: Before proceeding with the part replacement:
1. Log into CAM.
2. Go to "Storage Systems" -> [your arrayname] -> "Administration" -> "Array Health Monitoring".
3. Uncheck the box "Enable ASR for this array" under the section "Monitoring for This Array". If the box is already unchecked, there is no action required. Remember the status however, as it will matter in step 3 of REACTIVATING ASR WITH CAM 6.9 OR EARLIER below.
4. Click on "Save" if you have unchecked the box in step 3 above.
1. Using CAM, verify the controller status as OFFLINE. If it is not OFFLINE, use the Service Advisor for the array under Place the Controller Offline.
2. Use the Service Advisor procedure for Controller Removal and Replacement to replace the controller.
NOTE: Once the controller is removed from its slot, you must insert the controller air blocker into the open controller slot to ensure the correct airflow. This step is not covered in the attached video demonstration.
NOTE: Please be aware to transfer the battery from the original controller into the new replacement controller. This step is also mentioned in CAM Service Advisor
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
1. Alarms for Offline Controller, RPA Memory Error, Drive Tray Lost Redundancy, and Drive Path Degraded no longer present on the system.
2. Controllers are both in an Online Status
3. Check for any Volumes not on their preferred path, look at the hosts that access them, and failback the paths.
REACTIVATING ASR with CAM 6.10: ASR is automatically deactivated when you select "Reserve the tray for maintenance" in Service Advisor, and it is reactivated when you select "Release the tray from maintenance" in Service Advisor. If ASR was not enabled before beginning this procedure, selecting "Release the tray from maintenance" will not activate it.
REACTIVATING ASR WITH CAM 6.9 OR EARLIER: After proceeding with the part replacement:
1. Log into CAM.
2. Go to "Storage Systems" -> [your arrayname] -> "Administration" -> "Array Health Monitoring".
3. Check the box "Enable ASR for this array" under the section "Monitoring for This Array". Do this ONLY if you unchecked the box in step 3 of DEACTIVATING ASR WITH CAM 6.9 OR EARLIER. If you found the box was unchecked, leave it unchecked now.
4. Click on "Save" if you have checked the box to reactivate ASR.
REFERENCE INFORMATION: The Service Advisor in CAM
Attachments
This solution has no attachment