Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1392351.1
Update Date:2014-12-04
Keywords:

Solution Type  Technical Instruction Sure

Solution  1392351.1 :   Pillar Axiom: How to Decode the Pillar Axiom ISCSI Session Login Reason Code  


Related Items
  • Pillar Axiom 500 Storage System
  •  
  • Pillar Axiom 600 Storage System
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>Axiom>SN-DK: Ax600
  •  




In this Document
Goal
Solution


Applies to:

Pillar Axiom 500 Storage System - Version Not Applicable and later
Pillar Axiom 600 Storage System - Version Not Applicable and later
Information in this document applies to any platform.

Goal

This document describes reason codes returned from  iSCSI  Login Sessions 

 

To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - Disk Storage Pillar Axiom System

Solution


The below example is from an Email Alert but the same information could be in the Event log as well.

Event name: iSCSI Session Login Failed
Date occurred: 2010-09-17T14:31:55-05:00
Parameters:
Details = 0
InitiatorDeviceName = 65535
InitiatorIPAddress = 10.10.13.20
Reason = 12
iSCSIPort = 0

The following are a list of reason codes to help debug the issue.

SAN_ISCSI_LOGIN_FAILURE_NONE = 0

SAN_ISCSI_LOGIN_FAILURE_PROTOCOL_ERROR = 1

SAN_ISCSI_LOGIN_FAILURE_VERSION_MISMATCH = 2

SAN_ISCSI_LOGIN_FAILURE_SESSION_NOT_FOUND = 3

SAN_ISCSI_LOGIN_FAILURE_INITIATOR_TASK_NOT_FOUND = 4

SAN_ISCSI_LOGIN_FAILURE_MULTIPLE_CONNECTIONS_NOT_ALLOWED = 5

SAN_ISCSI_LOGIN_FAILURE_CONNECTION_REINSTATEMENT_NOT_ALLOWED = 6

SAN_ISCSI_LOGIN_FAILURE_INITIATOR_NOT_PERMITTED = 7

SAN_ISCSI_LOGIN_FAILURE_TARGET_NAME_MISMATCH = 8

SAN_ISCSI_LOGIN_FAILURE_AUTHENTICATION_STAGE_REQUIRED = 9

SAN_ISCSI_LOGIN_FAILURE_INITIATOR_CHAP_NOT_CONFIGURED = 10

SAN_ISCSI_LOGIN_FAILURE_TARGET_CHAP_NOT_CONFIGURED = 11

SAN_ISCSI_LOGIN_FAILURE_UNKNOWN_AUTH_METHOD = 12

SAN_ISCSI_LOGIN_FAILURE_UNKNOWN_CHAP_ALGORITHM = 13

SAN_ISCSI_LOGIN_FAILURE_CHAP_NAME_MISMATCH = 14

SAN_ISCSI_LOGIN_FAILURE_CHAP_AUTHENTICATION_FAILED = 15

SAN_ISCSI_LOGIN_FAILURE_IMMEDIATE_DATA_NOT_SUPPORTED = 16

SAN_ISCSI_LOGIN_FAILURE_EXPECTED_KEY_NOT_FOUND = 17

SAN_ISCSI_LOGIN_FAILURE_MAX_LTDS_LENGTH_EXCEEDED = 18

SAN_ISCSI_LOGIN_FAILURE_PDU_TRANSFER_ERROR = 19

SAN_ISCSI_LOGIN_FAILURE_MAX_REQUEST_COUNT_EXCEEDED = 20

SAN_ISCSI_LOGIN_FAILURE_TIMEOUT_WAITING_FOR_HOST_PDU = 21



In the example event the reason number can be translated using the Reason Codes above. In this instance the event returned Reason Code 12 which maps to SAN_ISCSI_LOGIN_FAILURE_UNKNOWN_AUTH_METHOD where the client could be mis-configured to use an authentication method unsupported by the Axiom.

Event name: iSCSI Session Login Failed
Date occurred: 2010-09-17T14:31:55-05:00
Parameters:
Details = 0
InitiatorDeviceName = 65535
InitiatorIPAddress = 10.10.13.20
Reason = 12
iSCSIPort = 0


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.