CAM - How to Remove and Replace 2500/2500-M2 IOM [VCAP]
Related Items |
- Sun Storage 2530-M2 Array
- Sun Storage 2540 Array
- Sun Storage 2510 Array
- Sun Storage 2530 Array
- Sun Storage 2540-M2 Array
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: DISK-CAP VCAP
- Microlearning>Video>ML-VID-VCAP
- _KM>Content>Video
|
In this Document
Applies to:
Sun Storage 2540-M2 Array - Version All Versions to All Versions [Release All Releases]
Sun Storage 2510 Array - Version All Versions to All Versions [Release All Releases]
Sun Storage 2530 Array - Version All Versions to All Versions [Release All Releases]
Sun Storage 2540 Array - Version All Versions to All Versions [Release All Releases]
Sun Storage 2530-M2 Array - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Goal
How to remove and replace a 2500/2500-M2 IOM in CAM
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:
None. This is a Customer Replaceable Unit with no training requirement.
TIME ESTIMATE: 30 minutes
TASK COMPLEXITY: 0
FIELD ENGINEER INSTRUCTIONS
PROBLEM OVERVIEW:
Expansion tray IOM has been determined to be failed or in need of replacement.
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY:
The IOM is hot swappable and can be replaced with the array powered on.
WHAT ACTION DOES THE ENGINEER/ADMINISTRATOR NEED TO TAKE:
NOTE: If ASR is enabled, it should be deactivated temporarily before servicing the equipment so that additional unnecessary Service Requests are not created.
DEACTIVATING ASR WITH CAM 6.10: ASR is automatically deactivated when you select "Reserve the tray for maintenance" in Service Advisor, and it is reactivated when you select "Release the tray from maintenance" in Service Advisor.
DEACTIVATING ASR WITH CAM 6.9 OR EARLIER: Before proceeding with the part replacement:
1. Log into CAM.
2. Go to "Storage Systems" -> [your arrayname] -> "Administration" -> "Array Health Monitoring".
3. Uncheck the box "Enable ASR for this array" under the section "Monitoring for This Array". If the box is already unchecked, there is no action required. Remember the status however, as it will matter in step 3 of REACTIVATING ASR WITH CAM 6.9 OR EARLIER below.
4. Click on "Save" if you have unchecked the box in step 3 above.
1. Use the Service Advisor (SA) procedure for I/O Module (IOM) Removal/Replacement to replace the IOM.
2. Remove and replace the IOM per the SA instructions, noting position of the cabling, and location of any SFPs removed from the original IOM.
3. Restore SFPs and drive tray cabling
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
1. Verify that the IOM status is OK
2. Verify that there is no Drive Tray Lost Redundancy, Failed IOM, alarms on the array. This can take up to 5 minutes
3. Verify the IOM firmware is the same for both IOMs in the same tray. If not, have it updated.
REACTIVATING ASR with CAM 6.10: ASR is automatically deactivated when you select "Reserve the tray for maintenance" in Service Advisor, and it is reactivated when you select "Release the tray from maintenance" in Service Advisor. If ASR was not enabled before beginning this procedure, selecting "Release the tray from maintenance" will not activate it.
REACTIVATING ASR WITH CAM 6.9 OR EARLIER: After proceeding with the part replacement:
1. Log into CAM.
2. Go to "Storage Systems" -> [your arrayname] -> "Administration" -> "Array Health Monitoring".
3. Check the box "Enable ASR for this array" under the section "Monitoring for This Array". Do this ONLY if you unchecked the box in step 3 of DEACTIVATING ASR WITH CAM 6.9 OR EARLIER. If you found the box was unchecked, leave it unchecked now.
4. Click on "Save" if you have checked the box to reactivate ASR.
PARTS NOTE:
IOM CRUs are NOT the same between the 25x0 and the 25x0-M2
REFERENCE INFORMATION: The Service Advisor in CAM