Asset ID: |
1-71-1390234.1 |
Update Date: | 2016-03-16 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1390234.1
:
How to Remove and Replace a SPARC Enterprise T5440 Power Supply:ATR:1390234.1:0
Related Items |
- Sun SPARC Enterprise T5440 Server
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
In this Document
Applies to:
Sun SPARC Enterprise T5440 Server - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to remove and replace a T5440 Power Supply (CRU)
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS ARE REQUIRED:
No special skills required, Customer Replaceable Unit (CRU) procedure
TIME ESTIMATE: 30 minutes
TASK COMPLEXITY: 0
NOTE: Never replace a 2nd Edition PSU with a 1st Edition PSU. Please refer to the appropriate product section in the Sun System Handbook: http://support.oracle.com/handbook_private/Systems/SE_T5440/component.power.html . The 2nd Edition PSU will include "2nd Edition" in the part description, "1st Edition" will not.
REMOVAL/REPLACEMENT INSTRUCTIONS
PROBLEM OVERVIEW: Power supply failure
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?: N/A
The server is equipped with redundant hot-swappable power supplies. Redundant power supplies enable you to remove and replace a power supply without shutting the server down, provided that at least two other power supplies are online and working.
WHAT ACTIONS ARE REQUIRED:
A) Remove a Power Supply
1. Identify which power supply requires replacement. An amber LED on a power supply indicates that a failure was detected. In addition, the show faulty command indicates which power supply is faulty.
2. Follow standard ESD precautions. Access to the rear of the server where the faulty power supply is located. If necessary, slide the system partially out of the rack to obtain better access to the rear panel.
3. Disconnect the power cord from the faulty power supply.
4. Grasp the power supply handle and press the release latch.
5. Pull the power supply out of the chassis.
Note: Power supply zero (PS 0) is lower slot, Power supply 3 (PS 3) is in the upper slot. If you are servicing Power Supply 0, you have to disconnect the cable management arm support strut.
B) Install a Power Supply
1. Align the replacement power supply with the empty power supply bay.
2. Slide the power supply into the bay until it is fully seated.
3. Reconnect the power cord to the power supply. Verify that the power supply LED is green or blinking green.
4. Verify that the system Power Supply Fault LED, and the front and rear Service Required LEDs are not lit.
5. At the Oracle ILOM -> prompt, use the show faulty command to verify the status of the power supplies.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE: N/A
PARTS NOTE:
For more details, refer to http://support.oracle.com/handbook_private/Systems/SE_T5440/component.power.html
REFERENCE INFORMATION:
http://docs.oracle.com/cd/E19488-01/index.html
Attachments