Applies to:Sun Storage 7410 Unified Storage System - Version All Versions and laterSun ZFS Storage 7320 - Version All Versions and later Sun Storage 7210 Unified Storage System - Version All Versions and later Sun Storage 7110 Unified Storage System - Version All Versions and later Sun ZFS Storage 7120 - Version All Versions and later 7000 Appliance OS (Fishworks) GoalPreliminary work to identify NDMP type issues, gather necessary information and data for further analysis. Further data collection may be required depending on the nature of the problem. To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - Disk Storage ZFS Storage Appliance Community
SolutionIdentifying NDMP type issues- NDMP type issues are generally identified when backup software has failed, when errors/warnings are generated, or a backup/restore is performing slowly. Appliance general health.
Dec 10 01:32:57 lab /usr/lib/ndmp/ndmpd[1880]: [ID 702911 daemon.error] Tape read error: I/O error.
Appliance NDMP general health
Frame and describe the problemDescribe the problem as seen on ZFS Storage Appliance and on the Data Management Application (DMA) backup software.
- On DMA backup software
Data collectionList of general information and data that needs to be collected.
Depending on the problem, you may need to capture more data before collecting a supportbundle * for suspected ndmp code aksh> confirm shell gcore -o /var/ak/dropbox/ndmpd.gcore `pgrep ndmpd`
* Capture ndmp debug when escalating to engineering. Starting with the 2011.1.1.0 appliance code, ndmp logging is always enabled (CR 6908633). The log is available at /var/ak/logs/ndmp/ndmplog. * Capture network snoop between DMA and ZFS Storage Appliance. Preferably from an external device to the ZFS Storage Appliance, but if required capture a network trace from the ZFS Storage Appliance itself. See Document 1398376.1 Sun Storage 7000 Unified Storage System: How to get a network trace to assist in troubleshooting network problems. (*) By default NDMP uses TCP/IP port 10000. NDMP version 4 can be configured to use a different port number.
References<NOTE:1019887.1> - Sun Storage 7000 Unified Storage System: How to Collect a Support Bundle using the BUI or CLI<NOTE:1398376.1> - Sun Storage 7000 Unified Storage System: How to get a Network Trace to assist in Troubleshooting Network Problems <NOTE:1387930.1> - Sun Storage 7000 Unified Storage System: How to Troubleshoot NDMP Issues <BUG:6908633> - WCREG14:PAGE UNACCESSIBLE AFTER DEPLOYMENT WITRH WORKLITS AND PERSONAL TASK Attachments This solution has no attachment |
||||||||||||||||||||||
|