Solution Type Technical Instruction Sure Solution 1376822.1 : Sun SPARC[TM] Enterprise M3000, M4000, M5000, M8000, M9000: The Output of XSCF's command showdomainstatus May Cause Confusion.
The output of showdomainstatus may cause confusion. In this Document
Created from <SR 3-4851227481> Applies to:Sun SPARC Enterprise M5000 Server - Version Not Applicable and laterSun SPARC Enterprise M9000-32 Server - Version Not Applicable and later Sun SPARC Enterprise M3000 Server - Version Not Applicable and later Sun SPARC Enterprise M9000-64 Server - Version Not Applicable and later Sun SPARC Enterprise M4000 Server - Version Not Applicable and later Information in this document applies to any platform. GoalThe "showdomainstatus -a" command on XSCF displays different states even though both domains are at the ok> prompt: XSCF> showdomainstatus -a DID Domain Status 00 OpenBoot Execution Completed 01 Booting/OpenBoot PROM prompt 02 - 03 - SolutionThese are the correct states: domain 0 is powered off and on, while domain 01 was brought down from the O.S. XSCF> showdomainstatus -a DID Domain Status 00 OpenBoot Execution Completed <--- Domain powered off and then on, or "reset-all" performed while at ok prompt 01 Booting/OpenBoot PROM prompt <--- Domain brought down with init 0 etc... 02 - 03 -
Check man pages directly for further domain states description. To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in an appropriate My Oracle Support Community, Oracle Sun Technologies Community.