Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1376679.1
Update Date:2014-10-17
Keywords:

Solution Type  Technical Instruction Sure

Solution  1376679.1 :   How to determine if a drive is internal or external (Enterprise Classic)  


Related Items
  • Sun Enterprise 5500 Server
  •  
  • Sun Enterprise 4000 Server
  •  
  • Sun Enterprise 5000 Server
  •  
  • Sun Enterprise 6000 Server
  •  
  • Sun Enterprise 6500 Server
  •  
  • Sun Enterprise 4500 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: Exx00
  •  
  • _Old GCS Categories>Sun Microsystems>Servers>Midrange Servers
  •  




In this Document
Goal
Fix


Applies to:

Sun Enterprise 6500 Server - Version Not Applicable and later
Sun Enterprise 5500 Server - Version Not Applicable and later
Sun Enterprise 4000 Server - Version Not Applicable and later
Sun Enterprise 4500 Server - Version Not Applicable and later
Sun Enterprise 6000 Server - Version Not Applicable and later
Information in this document applies to any platform.

Goal

Determine if a disk on a Ultra Enterprise Sunfire Classic machine is internal or external

Fix

The first thing to look at is prtdiag -v output.
If the machine has a disk board it will appear like this:

Detached Boards
===============
   Slot     State     Type       Info
   ----     -----     -----      ----------------------------------
    15     disabled    disk      Disk 0: Target: 10  Disk 1: Target 11

Because disk boards are connected to the scsi bus via external cables
just like an external disk pack/array, it is often difficult to determine if a disk on an Enterprise classic 4000 / 4500 / 5000 / 5500 / 6000 /6500 is internal to the server or external.

Another clue to determine if the disk is internal, is to note the SCSI target ID of the disk.
The default SCSI ID numbers for disk drives on the Disk boards are
determined by the following table copied from appendix  C in
Doc: Sun 6500 / 5500 / 4500 Enterprise Systems Reference Manual



Board SlotDisk 0 (On disk board)Disk 1 (On disk Board)
0 4 5
1 6 7
2 0 1
3 10 11
4 2 3
5 12 13
6 8 9
7 14 15
14 0 1
15 10 * 11 *
     
     



*Enterprise 6500 systems: Disk boards can only be installed in slots
14 and 15.

Another thing to be aware of is the sizes of disks supported on the internal disk boards
This will give you a clue if the disk in question is internal or external.

A disk board contains 2 disks:

2 X 2.1 gig 7200 rpm
2 X 4.2 gig 7200 rpm
2 X 9.1 gig 7200 rpm
2 X 18.2 gig 10000 rpm


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback