![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||||
Solution Type Technical Instruction Sure Solution 1375010.1 : Sun Storage 7000 Unified Storage System: How to Collect Analytics Data for Fibre Channel Performance Issues
In this Document
Applies to:Sun ZFS Storage 7120 - Version All Versions and laterSun Storage 7210 Unified Storage System - Version All Versions and later Sun Storage 7110 Unified Storage System - Version All Versions and later Oracle ZFS Storage ZS3-BA - Version All Versions and later Oracle ZFS Storage ZS3-2 - Version All Versions and later 7000 Appliance OS (Fishworks) NAS head revision : [2010.Q1 and beyond] BIOS revision : [not dependent] ILOM revision : [not dependent] JBODs Model : [not dependent] CLUSTER related : [not dependent] GoalTo provide guidance on collecting analytics data for troubleshooting Fibre Channel performance issues. To review the system's Fibre Channel performance and any problems associated with it, collecting the following statistics from analytics will be useful. These are top level statistics, an Oracle Support engineer may request more specific statistics as and when the understanding of the problem deepens. To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - Disk Storage ZFS Storage Appliance Community
SolutionStatistics to collect:CPU: percent utilization PLEASE NOTE: The analytics noted in this document should only be run on an "as needed" basis and NOT run on a permanent basis as this may cause BUI/CLI as well as operational performance issues.
Steps to Follow:1. In the BUI under the "Analytics -> Open Worksheets" page, use "+" icon to add the above statistics, and save the worksheet with a meaningful name eg: 'fcperf'. Now close the worksheet and the datasets will continue to run in the background.
3. Provide the name of the file which was uploaded, the date time and TZ of the problem to the support engineer.
Back to Document 1331769.1 - Sun Storage 7000 Unified Storage System: How to Troubleshoot Performance Issues.
****Checked for currency - 01-NOV-2015****
References<NOTE:1331769.1> - Sun Storage 7000 Unified Storage System: How to Troubleshoot Performance IssuesAttachments This solution has no attachment |
||||||||||||||||||||||
|