![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Technical Instruction Sure Solution 1373599.1 : ODA Oracle Database Appliance Bare Metal Restore Procedure X5-2 and X6-2
Applies to:Oracle Database Appliance X6-2 HA Hardware - Version All Versions to All Versions [Release All Releases]Oracle Database Appliance Software - Version 12.1.2.2 to 12.1.2.12 [Release 12.1] Oracle Database Appliance - Version All Versions to All Versions [Release All Releases] Oracle Database Appliance X5-2 - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. GoalOracle Database Appliance ships from the factory with OS and Appliance Manager Pre-Installed. The document outlines the steps to be performed if there is a need to Re-image the complete ODA.
Comment: ILOM options can change between versions:
This note's steps below are specific to ODA X5-2 and X6-2 Click on the following link for a pdf outlining pre-X5-2 ODA steps Bare Metal Restore.
SolutionX5-2 version Steps are as follows:
COMMENT: Upgrading the different Infra / GRID components are covered in different notes
- Refer to Note 888888.1 for more information and join the ODA Community!
Example of ODA X3-2 12.1.2.2.0 login as: root
root@odax1's password: [root@odax3rm1 ~]# oakcli show version -detail Reading the metadata. It takes a while... System Version Component Name Installed Version Supported Version --------------------------------------------------------- 12.1.2.2.0 Controller_INT 11.05.03.00 Up-to-date Controller_EXT 11.05.03.00 Up-to-date Expander 0018 Up-to-date SSD_SHARED 944A Up-to-date HDD_LOCAL A606 A690 HDD_SHARED A690 Up-to-date ILOM 3.1.2.42 r88414 3.2.4.26 r93813 BIOS 17100400 17110200 IPMI 1.8.12.0 Up-to-date HMP 2.3.2.0.1 Up-to-date OAK 12.1.2.2.0 Up-to-date OL 5.11 Up-to-date GI_HOME 12.1.0.2.2(19769480, Up-to-date 19769479) DB_HOME 12.1.0.2.2(19769480, Up-to-date 19769479)
Example of ODA V1 2.6.0.0.0 - Older version output [root@oak1 ~]# time /opt/oracle/oak/bin/oakcli validate -c SystemComponents INFO: oak system information and Validations RESULT: System Software inventory details Reading the metadata. It takes a while... System Version Component Name Installed Version Supported Version -------------- --------------- ------------------ ----------------- 2.6.0.0.0 Controller¹ 05.00.29.00 11.05.02.00 Expander¹ 0342 Up-to-date SSD_SHARED¹ E125 E12B HDD_LOCAL¹ SA03 Up-to-date HDD_SHARED¹ 0A25 0B25 ILOM¹ 3.0.14.13 r66865 3.0.16.22.b r78329 BIOS¹ 12010303 12010310 IPMI¹ 1.8.10.5 Up-to-date HMP¹ 2.2.6.1 Up-to-date OAK¹ 2.6.0.0.0 Up-to-date OEL¹ 5.8 Up-to-date TFA³ 2.5.1.4 Up-to-date GI_HOME¹ 11.2.0.3.6(16056266, Up-to-date 16083653) DB_HOME² 11.2.0.3.6(16056266, Up-to-date 16083653) ASR³ Unknown 4.4 " 1 - ¹ Updated using ODA Infra and Grid patching -- Strongly recommended as soon as available regardless of RDBMS versions used
: Should match or be higher than RDBMS 2 - ² Updated using ODA RDBMS patch or RDBMS Clone files -- Recommended to always be applied for latest PSU : Should be in sync with Grid / Infra patches & and always patched AFTER the ODA Infra / Grid is patched 3 - ³ Updated with ODA patching but may also have independent patching : Check note 888888.1 for more information ODA + Vitualization Installation / Upgrade / Patching Steps are referenced in Note 888888.1 and / or the associated version README files
INTERNAL
Oracle Database Appliance : How to perform Bare Metal Restore of a Single node on ODA 12.1.x(Doc ID 1964234.1) Note: Single Node restore of ODAVP ( Virtualized platform ) is not currently supported.
Community DiscussionsStill have questions? Use the communities window below to search for similar discussions or start a new discussion on this subject. (Window is the live community not a screenshot) Click here to open in main browser window References<NOTE:1469963.1> - Oracle Database Appliance : How to perform Bare Metal Restore of a Single node on ODA 2.x<NOTE:1373617.1> - Oracle Database Appliance (ODA) End User Deployment 2.1.0.0 to 2.10.0.0 <NOTE:888888.1> - Oracle Database Appliance - 18.1, 12.X, and 2.X Supported ODA Versions & Known Issues <NOTE:1964234.1> - Oracle Database Appliance : How to perform Bare Metal Restore of a Single node on ODA 12.1.x Attachments This solution has no attachment |
||||||||||||
|