Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1373599.1
Update Date:2018-05-09
Keywords:

Solution Type  Technical Instruction Sure

Solution  1373599.1 :   ODA Oracle Database Appliance Bare Metal Restore Procedure X5-2 and X6-2  


Related Items
  • Oracle Database Appliance
  •  
  • Oracle Database Appliance X5-2
  •  
  • Oracle Database Appliance X6-2 HA Hardware
  •  
  • Oracle Database Appliance Software
  •  
Related Categories
  • PLA-Support>Eng Systems>Exadata/ODA/SSC>Oracle Database Appliance>DB: ODA_EST
  •  
  • _Old GCS Categories>ST>Server>Engineered Systems>Oracle Database Appliance>Install
  •  




Applies to:

Oracle Database Appliance X6-2 HA Hardware - Version All Versions to All Versions [Release All Releases]
Oracle Database Appliance Software - Version 12.1.2.2 to 12.1.2.12 [Release 12.1]
Oracle Database Appliance - Version All Versions to All Versions [Release All Releases]
Oracle Database Appliance X5-2 - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

Oracle Database Appliance ships from the factory with OS and Appliance Manager Pre-Installed. The document outlines the steps to be performed if there is a need to Re-image the complete ODA.
This procedure is also commonly referred to as a "Bare Metal Restore"

  • Bare Metal Restore (OS Re-Imaging) is specific to the node on which the procedure is executed and will overwrite the local storage (OS) on that node
  • Reimaging an ODA needs to be done on both nodes.
  • Bare Metal OS Re-Imaging does not patch the firmware (BIOS/ILOM etc).
    - BM only re-images the local system disk from an OS perspective
  • ODA + Virtualization (ODAVP) requires different binaries / ISO than non-ODAVP (available as of ODA 2.5.x and higher)
    - See Note 888888.1 for descriptions and links

 

 

Comment: ILOM options can change between versions:  
 This note's steps below are specific to ODA X5-2 and X6-2
Click on the following link for a pdf outlining pre-X5-2 ODA steps Bare Metal Restore.

 

Solution

X5-2 version Steps are as follows:

X5-2 Step 1

X5-2 Step 2

X5-2 Step 3

X5-2 Step 4

X5-2 Step 5

X5-2 Step 6

X5-2 Step 7

X5-2 Step 8

X5-2 Step 9

 

COMMENT:

Upgrading the different Infra / GRID components are covered in different notes
- Refer to Note 888888.1 for more information and join the ODA Community!

 

Example of ODA X3-2 12.1.2.2.0

login as: root
root@odax1's password:

[root@odax3rm1 ~]# oakcli show version -detail
Reading the metadata. It takes a while...
System Version
    Component Name  Installed Version     Supported Version
    ---------------------------------------------------------
12.1.2.2.0
    Controller_INT    11.05.03.00          Up-to-date    
    Controller_EXT    11.05.03.00          Up-to-date
    Expander                 0018          Up-to-date
    SSD_SHARED               944A          Up-to-date
    HDD_LOCAL                A606          A690
    HDD_SHARED               A690          Up-to-date
    ILOM          3.1.2.42 r88414          3.2.4.26 r93813
    BIOS                 17100400          17110200
    IPMI                 1.8.12.0          Up-to-date
    HMP                 2.3.2.0.1          Up-to-date
    OAK                12.1.2.2.0          Up-to-date
    OL                       5.11          Up-to-date
    GI_HOME   12.1.0.2.2(19769480,         Up-to-date
                         19769479)
    DB_HOME   12.1.0.2.2(19769480,         Up-to-date
                         19769479)

 

Example of ODA V1 2.6.0.0.0 - Older version output


[root@oak1 ~]# time /opt/oracle/oak/bin/oakcli validate -c SystemComponents
INFO: oak system information and Validations

 RESULT: System Software inventory details
 Reading the metadata. It takes a while...
 System Version  Component Name            Installed Version         Supported Version
 --------------  ---------------           ------------------        -----------------
 2.6.0.0.0
                 Controller¹                05.00.29.00               11.05.02.00
                 Expander¹                  0342                      Up-to-date
                 SSD_SHARED¹                E125                      E12B
                 HDD_LOCAL¹                 SA03                      Up-to-date
                 HDD_SHARED¹                0A25                      0B25
                 ILOM¹                      3.0.14.13 r66865          3.0.16.22.b r78329
                 BIOS¹                      12010303                  12010310
                 IPMI¹                      1.8.10.5                  Up-to-date
                 HMP¹                       2.2.6.1                   Up-to-date
                 OAK¹                       2.6.0.0.0                 Up-to-date
                 OEL¹                       5.8                       Up-to-date
                 TFA³                       2.5.1.4                   Up-to-date
                 GI_HOME¹                   11.2.0.3.6(16056266,      Up-to-date
                                            16083653)
                 DB_HOME²                   11.2.0.3.6(16056266,      Up-to-date
                                            16083653)
                 ASR³                       Unknown                   4.4
"
1 - ¹ Updated using ODA Infra and Grid patching  -- Strongly recommended as soon as available regardless of RDBMS versions used
      : Should match or be higher than RDBMS

2 - ² Updated using ODA RDBMS patch or RDBMS Clone files -- Recommended to always be applied for latest PSU                    
      : Should be in sync with Grid / Infra patches & and always patched AFTER the ODA Infra / Grid is patched

3 - ³ Updated with ODA patching but may also have independent patching
      : Check note 888888.1 for more information
 
ODA + Vitualization Installation / Upgrade / Patching Steps are referenced in Note 888888.1 and / or the associated version README files
 
 

 

INTERNAL


Related

Oracle Database Appliance : How to perform Bare Metal Restore of a Single node on ODA 12.1.x(Doc ID 1964234.1)
Oracle Database Appliance : How to perform Bare Metal Restore of a Single node on ODA 2.x(Doc ID 1469963.1)

Note: Single Node restore of ODAVP ( Virtualized platform ) is not currently supported.

 

 

Community Discussions

Still have questions? Use the communities window below to search for similar discussions or start a new discussion on this subject. (Window is the live community not a screenshot)

Click here to open in main browser window

References

<NOTE:1469963.1> - Oracle Database Appliance : How to perform Bare Metal Restore of a Single node on ODA 2.x
<NOTE:1373617.1> - Oracle Database Appliance (ODA) End User Deployment 2.1.0.0 to 2.10.0.0
<NOTE:888888.1> - Oracle Database Appliance - 18.1, 12.X, and 2.X Supported ODA Versions & Known Issues
<NOTE:1964234.1> - Oracle Database Appliance : How to perform Bare Metal Restore of a Single node on ODA 12.1.x

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback