![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 1367458.1 : Is "ipmievd" required on SPARC systems (T5xx0 / T3-x)?
"ipmievd" service / daemon not needed on SPARC CMT systems. In this Document
Applies to:SPARC T3-1 - Version Not Applicable and laterSun SPARC Enterprise T5440 Server - Version Not Applicable and later SPARC T3-2 - Version Not Applicable and later SPARC T3-4 - Version Not Applicable and later Sun Blade T6340 Server Module - Version Not Applicable and later Oracle Solaris on SPARC (64-bit) GoalIf you see errors like: Aug 24 06:12:32 xxxxxxx ldc: [ID 490484 kern.warning] WARNING: ldc_close: (0xb) channel RX queue unconf failed
Aug 24 06:12:33 xxxxxxx ipmievd: [ID 702911 daemon.error] Get SEL Info command failed: Unknown (0x7e) Aug 24 06:12:35 xxxxxxx ipmievd: [ID 702911 daemon.error] Get SEL Entry 0 command failed: Unknown (0x7e) or Oct 4 10:15:26 xxxxxxx ipmievd: Error obtaining SDR info: Timeout
Oct 4 10:15:26 xxxxxxx ipmievd: Unable to open SDR for reading Oct 4 10:15:41 xxxxxxx ipmievd: Get SEL Info command failed: Timeout
# svcs ipmievd
STATE STIME FMRI online Sep_15 svc:/network/ipmievd:default Solution"ipmievd" is part of the IPMI tool package ("SUNWipmi" or "ipmitool"). # svcadm disable ipmievd
Attachments This solution has no attachment |
||||||||||||||
|