Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1365521.1
Update Date:2017-11-30
Keywords:

Solution Type  Technical Instruction Sure

Solution  1365521.1 :   How to Remove and Replace a V210/V240 Front Bezel Assembly:ATR:1365521.1:1  


Related Items
  • Sun Fire V240 Server
  •  
  • Sun Fire V210 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
Goal
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP

Applies to:

Sun Fire V210 Server - Version Not Applicable to Not Applicable [Release N/A]
Sun Fire V240 Server - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Goal

How to Remove and Replace a V210/V240 Front Bezel Assembly

********************************************************************************
To report errors or request improvements on this procedure,
please go to http://support.us.oracle.com and Add a comment for Doc ID: 1365521.1
********************************************************************************

Solution

DISPATCH INSTRUCTIONS

- WHAT SKILLS DOES THE ENGINEER NEED:
V210/V240 server product training

- TIME ESTIMATE: 240 minutes

- TASK COMPLEXITY: 1

FIELD ENGINEER INSTRUCTIONS:

- PROBLEM OVERVIEW:
Front bezel assembly not working

- WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
The front bezel assembly includes the bezel, the front server status indicators, and hinges. It is replaced as a single unit.

Removing the Front Bezel Assembly:

1.Power off the server.
2.Ensure the server is properly grounded.
3.Hold the bezel firmly at both ends and rotate it down to its open position.

Grip the bezel at the points marked by the green triangles at each end to open it.
Do not attempt to open the bezel using a single gripping point or by holding the middle of the bezel as damage may occur.

4.Disconnect the cable connecting the bezel assembly to the server.
5.Unscrew the bezel hinges and remove them from the server.

Installing the new Front Bezel Assembly

1.Locate the new bezel and hinges onto the server and screw them to the server.
2.Reconnect the bezel cable.



OBTAIN CUSTOMER ACCEPTANCE:

- WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

Follow the start-up procedure as prepared by sys-admin. Customer should verify system is stable for return to production.

PARTS NOTE:

https://support.oracle.com/handbook_partner/Systems/SunFireV240/components.html

https://support.oracle.com/handbook_partner/Systems/SunFireV240_R/components.html

https://support.oracle.com/handbook_partner/Systems/SunFireV210/components.html

https://support.oracle.com/handbook_partner/Systems/SunFireV210_R/components.html



REFERENCE INFORMATION:
Refer to Service Manual and Admin Guide:
http://download.oracle.com/docs/cd/E19088-01/v240.srvr/819-4207-10/819-4207-10.pdf


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback