Goal
SL3000 - Re-Enable ILC and Check ComplexId After FRS-3.0 Code Upgrade
( Inner Library Communication )
Solution
After upgrading to FRS-3.0 code from older versions you need to check via the CLI that the ILC is still enabled and also check the setting of the complexId.
If you use SDP and/or use Port 1A for service, this is important to check.
Commands to check/set these values:
For COMPLEXID
config complexId print
Prints the current SDP complex ID
config complexId set [1-254]
Sets the complexId to the specific number for SDP (default is "1")
For ILC
config ilc print
prints ilc status
config ilc enable | disable
enable or disable the ilc