Asset ID: |
1-71-1349644.1 |
Update Date: | 2018-05-10 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1349644.1
:
How to Replace a Sun Fire X2270 M2 Front I/O Cable
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Applies to:
Sun Fire X2270 M2 Server - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.
Goal
How to Replace a Sun Fire X2270 M2 Front I/O Cable.
Solution
DISPATCH INSTRUCTIONS
- WHAT SKILLS DOES THE ENGINEER NEED:
- TIME ESTIMATE: 15 minutes
- TASK COMPLEXITY: 0
FIELD ENGINEER INSTRUCTIONS:
- PROBLEM OVERVIEW: Replacing the Front I/O Cable
- WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE
RESOLUTION ACTIVITY?:
System should be powered off prior to service.
- WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Remove
1. Prepare the server for service. See How to Prepare for Service.
2. Remove the air duct. See How to Remove the Air Duct.
3. Disconnect the I/O cable from the I/O board.
4. Disconnect the two I/O cable connections from the motherboard.
5. Carefully pull the I/O cable through the cutout in the chassis divider and lift it from the chassis.
Install
1. Connect the two I/O cable connections to the motherboard.
2. Carefully route the I/O cable through the cutout in the chassis divider and over the top of the HD partition.
3. Reconnect the I/O cable to the I/O board.
4. Check the routing of all cables for obstructions.
5. Prepare the server for operation.
OBTAIN CUSTOMER ACCEPTANCE
- WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO
AN OPERATIONAL STATE:
Power the system on.
PARTS NOTE:
https://support.oracle.com/handbook_private/Systems/SunFireX2270/components.html
REFERENCE INFORMATION:
Sun Fire X2270 M2 Server Internal Cabling.
Sun Fire X2270 M2 Server Service Manual
http://download.oracle.com/docs/cd/E19902-01/821-1345/
Attachments
This solution has no attachment