Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1349628.1
Update Date:2018-05-10
Keywords:

Solution Type  Technical Instruction Sure

Solution  1349628.1 :   How to Replace a Sun Fire X2270 M2 SATA Cable Harness  


Related Items
  • Sun Fire X2270 M2 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




In this Document
Goal
Solution


Applies to:

Sun Fire X2270 M2 Server - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Goal

How to Replace a Sun Fire X2270 M2 SATA Cable Harness.

Solution

DISPATCH INSTRUCTIONS
- WHAT SKILLS DOES THE ENGINEER NEED:
- TIME ESTIMATE:  10 minutes
- TASK COMPLEXITY: 0

FIELD ENGINEER INSTRUCTIONS:
- PROBLEM OVERVIEW:
- WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?:

A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.

Then power down the system and disconnect the Power Cord.

- WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

Remove
1. Prepare the server for service. See How to Prepare for Service.
2. Remove the air duct. See .How to Remove the Air Duct.
3. Disconnect the four SATA cables from the backplane.
4. Disconnect the four SATA cables from the motherboard connections.
5. Release the SATA cable harness from its tie-down points.
6. Carefully pull the SATA cable through the cutout in the chassis divider and lift it from the chassis.

Install
1. Match the color-coded SATA cables with their associated motherboard connections and connect the SATA cable connectors to the motherboard.
2. Carefully route the SATA cable through the cutout in the chassis divider.
3. Match the color-coded SATA cables with their associated backplane connection and connect the SATA cable connectors to the backplane.
4. Secure the SATA cable to the tie-down points.
5. Check the routing of all cables for obstructions.
6. Install the air duct. See How to Install the Air Duct.
7. Prepare the server for operation. See How to Prepare for Operation.


OBTAIN CUSTOMER ACCEPTANCE
- WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO
AN OPERATIONAL STATE:

PARTS NOTE:
https://support.oracle.com/handbook_private/Systems/SunFireX2270_M2/components.html

REFERENCE INFORMATION:
Sun Fire X2270 M2 Server Internal Cabling.

Sun Fire X2270 M2 Server Service Manual
http://download.oracle.com/docs/cd/E19902-01/821-1345/


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.